Heat pump noise: Determination and modelling of preference-equivalent levels

Air-to-water heat pumps are increasingly replacing traditional heating systems because of their environmental and energy benefits. However, noise emitted by their fans and compressors can cause complaints, even when regulatory limits are met. In this study, two listening experiments were conducted to examine heat pump noise by quantifying it as level penalties for equivalent loudness and preference. The study investigates how the preference-equivalent level differs from the loudness-equivalent level compared to a reference stimulus, and which psychoacoustic parameters best model the resulting level adjustments. Recordings from two heat pumps were auralised into a suburban residential setting and adjusted to an initial level of 60 dB(A). A two-alternative forced-choice (2-AFC) method with a 1-up-1-down rule is used to determine the point of subjective equality (PSE) for loudness and preference. Statistical analyses show significant differences between loudness-equivalent and preference-equivalent levels for eight of twelve stimuli. The median values further indicate that achieving equal preference relative to the reference generally requires lower sound pressure levels than achieving equal loudness, with the magnitude of this level offset varying across stimuli. Combining the results with psychoacoustic parameter analyses, two models based on linear regression were developed. This linear approach was chosen to ensure straightforward interpretability and robustness for the given stimulus set. Perceived loudness can be modelled by the psychoacoustic parameter loudness, while preference is best modelled by a linear combination of sharpness and roughness. These findings emphasise the need for perceptual metrics beyond A-weighted sound pressure levels when evaluating and optimising heat pump noise.

Authors

Institutions

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-04-03
DOI
https://doi.org/10.1051/aacus/2026016/pdf
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat pump noise: Determination and modelling of preference-equivalent levels

Lara Stürenburg, Hark Braren, Janina Fels, Lukas Aspöck
Springer Link (Chiba Institute of Technology)
Noise Effects and Management
article

Heat pump noise: Determination and modelling of preference-equivalent levels

Lara Stürenburg, Hark Braren, Janina Fels, Lukas Aspöck
article en

Abstract

Air-to-water heat pumps are increasingly replacing traditional heating systems because of their environmental and energy benefits. However, noise emitted by their fans and compressors can cause complaints, even when regulatory limits are met. In this study, two listening experiments were conducted to examine heat pump noise by quantifying it as level penalties for equivalent loudness and preference. The study investigates how the preference-equivalent level differs from the loudness-equivalent level compared to a reference stimulus, and which psychoacoustic parameters best model the resulting level adjustments. Recordings from two heat pumps were auralised into a suburban residential setting and adjusted to an initial level of 60 dB(A). A two-alternative forced-choice (2-AFC) method with a 1-up-1-down rule is used to determine the point of subjective equality (PSE) for loudness and preference. Statistical analyses show significant differences between loudness-equivalent and preference-equivalent levels for eight of twelve stimuli. The median values further indicate that achieving equal preference relative to the reference generally requires lower sound pressure levels than achieving equal loudness, with the magnitude of this level offset varying across stimuli. Combining the results with psychoacoustic parameter analyses, two models based on linear regression were developed. This linear approach was chosen to ensure straightforward interpretability and robustness for the given stimulus set. Perceived loudness can be modelled by the psychoacoustic parameter loudness, while preference is best modelled by a linear combination of sharpness and roughness. These findings emphasise the need for perceptual metrics beyond A-weighted sound pressure levels when evaluating and optimising heat pump noise.

Springer Link (Chiba Institute of Technology)
RWTH Aachen University (DE)
Openalex Percentile: Top 67%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.