Poster Session I - A67 ENDOSCOPIC POLYP SIZE MEASUREMENT USING A LASER-BASED SIZING PROBE: A PILOT STUDY

Abstract Background Accurate size measurement of colorectal polyps is important for planning polyp resection and post-polypectomy surveillance. Aims This study evaluated a through-the-scope laser-based probe for polyp size measurement during colonoscopies. Methods A prospective pilot study was conducted at CHUM in which polyps in enrolled patients were attempted to be measured with a laser-based probe. The primary outcome was the accuracy of laser-based polyp measurements, assessed as mean bias using microscopic sizing as the reference standard. Secondary outcomes included agreement with the reference standard, technical success rate, reasons for failed measurement, and per-polyp measurement time. Results Among 323 patients, laser-based measurement was attempted for 237 polyps; 149 had a microscopic size measurement. The technical success rate of the laser-based probe was 40.9% (97/237; 95% CI, 34.6%–47.5%), with mean time per measurement of 1:35. Accounting for specimens that could not be resected en bloc for microscopic measurements, a total of 41/149 (27.5%; 95% CI, 20.7%–35.5%) had paired laser-based and microscopy measurements for the primary analysis. Laser-based measurement demonstrated accurate sizing with minimal bias (–0.10 mm, 95% CI –0.30 to 0.10; P = 0.328) and met the 0.4 mm non-inferiority margin. Agreement with the reference was high (ICC = 0.91; 95% CI, 0.83–0.95), with near-perfect categorical concordance (kappa = 0.85) and 95.1% accuracy (39/41; 95% CI, 82.2–99.2). Bland–Altman limits of agreement ranged from –1.34 mm to 1.14 mm. Conclusions Laser-based measurement provided accurate polyp sizing when obtained. However, the technical success rate was limited by longer measurement times and device issues. Funding Agencies None

Authors

Institutions

Publication Details

Journal
Journal of the Canadian Association of Gastroenterology
Published
2026-02-01
DOI
https://doi.org/10.1093/jcag/gwaf042.067
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Poster Session I - A67 ENDOSCOPIC POLYP SIZE MEASUREMENT USING A LASER-BASED SIZING PROBE: A PILOT STUDY

Patrick Benoit, Roupen Djinbachian, Simon Bouchard, Victoire Michal et al.
Journal of the Canadian Association of Gastroenterology
Colorectal Cancer Screening and Detection
article

Poster Session I - A67 ENDOSCOPIC POLYP SIZE MEASUREMENT USING A LASER-BASED SIZING PROBE: A PILOT STUDY

Patrick Benoit, Roupen Djinbachian, Simon Bouchard, Victoire Michal, Preslava Aleksieva, Megan Oleksiw, Eric Cristea, Mohamed Zineddine Mahdadi, M Bouin, D Von Renteln, D C Daoud, R Battat, C Gefflot, J Liu
article en

Abstract

Abstract Background Accurate size measurement of colorectal polyps is important for planning polyp resection and post-polypectomy surveillance. Aims This study evaluated a through-the-scope laser-based probe for polyp size measurement during colonoscopies. Methods A prospective pilot study was conducted at CHUM in which polyps in enrolled patients were attempted to be measured with a laser-based probe. The primary outcome was the accuracy of laser-based polyp measurements, assessed as mean bias using microscopic sizing as the reference standard. Secondary outcomes included agreement with the reference standard, technical success rate, reasons for failed measurement, and per-polyp measurement time. Results Among 323 patients, laser-based measurement was attempted for 237 polyps; 149 had a microscopic size measurement. The technical success rate of the laser-based probe was 40.9% (97/237; 95% CI, 34.6%–47.5%), with mean time per measurement of 1:35. Accounting for specimens that could not be resected en bloc for microscopic measurements, a total of 41/149 (27.5%; 95% CI, 20.7%–35.5%) had paired laser-based and microscopy measurements for the primary analysis. Laser-based measurement demonstrated accurate sizing with minimal bias (–0.10 mm, 95% CI –0.30 to 0.10; P = 0.328) and met the 0.4 mm non-inferiority margin. Agreement with the reference was high (ICC = 0.91; 95% CI, 0.83–0.95), with near-perfect categorical concordance (kappa = 0.85) and 95.1% accuracy (39/41; 95% CI, 82.2–99.2). Bland–Altman limits of agreement ranged from –1.34 mm to 1.14 mm. Conclusions Laser-based measurement provided accurate polyp sizing when obtained. However, the technical success rate was limited by longer measurement times and device issues. Funding Agencies None

Journal of the Canadian Association of GastroenterologyVol. 9(Supplement_1)
Centre Hospitalier de l’Université de Montréal (CA)
Openalex Percentile: Top 56%
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.