De-coupling the Coriolis effect from Raman beams alignment in a fountain atom gravimeter

The alignment of Raman beams is important for high-precision atom interferometry gravimeters, and tilt modulation experiments are usually carried out to calibrate the direction of Raman beams. However, the Coriolis effect could be changed during the tilt modulation experiment, thus introducing a deviation in the alignment of Raman beams. In this work, a method of rotating the sensor head by 90° to eliminate the impact of the Coriolis effect on Raman beams' alignment in a fountain atom gravimeter was proposed and demonstrated experimentally. Using this method, the alignment uncertainty of the Raman beams in the atom gravimeter was reduced to 11 μrad, which contributed an uncertainty of less than 0.1 μGal (1 μGal = 1 × 10-8 m/s2) to the gravity measurement. Further simulations explained the experimental results and pointed out a way to reduce the Coriolis effect in atom gravimeters.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2026-02-01
DOI
https://doi.org/10.1063/5.0308195
Primary Topic
Geophysics and Gravity Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

De-coupling the Coriolis effect from Raman beams alignment in a fountain atom gravimeter

Hui-lin Zhou, Minkang Zhou, ZhongKun HU, LeLe CHEN et al.
Review of Scientific Instruments
Geophysics and Gravity Measurements
article

De-coupling the Coriolis effect from Raman beams alignment in a fountain atom gravimeter

Hui-lin Zhou, Minkang Zhou, ZhongKun HU, LeLe CHEN, Qin Luo, Xiaochun Duan, Li Li
article en

Abstract

The alignment of Raman beams is important for high-precision atom interferometry gravimeters, and tilt modulation experiments are usually carried out to calibrate the direction of Raman beams. However, the Coriolis effect could be changed during the tilt modulation experiment, thus introducing a deviation in the alignment of Raman beams. In this work, a method of rotating the sensor head by 90° to eliminate the impact of the Coriolis effect on Raman beams' alignment in a fountain atom gravimeter was proposed and demonstrated experimentally. Using this method, the alignment uncertainty of the Raman beams in the atom gravimeter was reduced to 11 μrad, which contributed an uncertainty of less than 0.1 μGal (1 μGal = 1 × 10-8 m/s2) to the gravity measurement. Further simulations explained the experimental results and pointed out a way to reduce the Coriolis effect in atom gravimeters.

Review of Scientific InstrumentsVol. 97(2)
Huazhong University of Science and Technology (CN), Wuhan Institute of Technology (CN)
Openalex Percentile: Top 60%
Geophysics and Gravity Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

De-coupling the Coriolis effect from Raman beams alignment in a fountain atom gravimeter — Hui-lin Zhou, Minkang Zhou, et al. · Review of Scientific Instruments (2026) | TGRS Research Map | TGRS