Loss-Optimal Modulation for an MMC-Based Triple-Active-Bridge Topology

This paper presents a loss-optimal modulation strategy for an MMC-based triple-active-bridge (TAB) converter that guarantees zero-voltage switching (ZVS). A switching pattern that blends penta phase-shift (PPS) and pulse-amplitude control (PAC) is proposed, and a generalized harmonic approximation (GHA)-based optimization is formulated to minimize total losses using device-calibrated switching and conduction loss models under power-balance and ZVS constraints. The optimization is solved offline over a grid spanning the operating space (power setpoints and dc-link voltages), and the resulting angles are stored in look-up tables for online deployment. Simulations demonstrate up to 44 % lower total losses than Phase-Shift Modulation and PPS, as well as lower conduction losses than PAC. In addition, the method expands the feasible operating region of the converter to power points that are not supported by PAC.

Authors

Institutions

Publication Details

Published
2025-12-01
DOI
https://doi.org/10.1109/spec64875.2025.11376842
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Loss-Optimal Modulation for an MMC-Based Triple-Active-Bridge Topology

Maurice Roes, George Papafotiou, Diego Vera
HVDC Systems and Fault Protection
article

Loss-Optimal Modulation for an MMC-Based Triple-Active-Bridge Topology

Maurice Roes, George Papafotiou, Diego Vera
article en

Abstract

This paper presents a loss-optimal modulation strategy for an MMC-based triple-active-bridge (TAB) converter that guarantees zero-voltage switching (ZVS). A switching pattern that blends penta phase-shift (PPS) and pulse-amplitude control (PAC) is proposed, and a generalized harmonic approximation (GHA)-based optimization is formulated to minimize total losses using device-calibrated switching and conduction loss models under power-balance and ZVS constraints. The optimization is solved offline over a grid spanning the operating space (power setpoints and dc-link voltages), and the resulting angles are stored in look-up tables for online deployment. Simulations demonstrate up to 44 % lower total losses than Phase-Shift Modulation and PPS, as well as lower conduction losses than PAC. In addition, the method expands the feasible operating region of the converter to power points that are not supported by PAC.

Eindhoven University of Technology (NL)
Affordable and clean energy
Openalex Percentile: Top 36%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.