Development and comparative study of rapid detection methods for Salmonella based on multiple molecular and immunological techniques

The detection of Salmonella in milk is critical for dairy safety, requiring rapid and sensitive methods. This study developed and compared three independent techniques: real-time PCR (qPCR), loop-mediated isothermal amplification (LAMP), and a gold immunochromatographic test strip (GICT), all targeting the invA gene. In artificially contaminated milk, qPCR achieved a detection limit of 10 3 CFU/mL with no cross-reactivity against non-target bacteria. LAMP amplification was completed within 30 min at 63°C, with detection limits of 4.17×10 3 CFU/mL (visual) and 4.17×10 2 CFU/mL (gel electrophoresis). The GICT strip, based on monoclonal antibody 8E7 1C8, showed a detection limit of 10 4 CFU/mL and remained stable for six months at 4°C. While qPCR and LAMP offered high sensitivity suitable for laboratory quantification, GICT provided a rapid, equipment-free option for on-site screening. Together, these methods provide a complementary toolkit for detecting Salmonella across laboratory and field settings.

Authors

Institutions

Publication Details

Journal
International Dairy Journal
Published
2026-02-13
DOI
https://doi.org/10.1016/j.idairyj.2026.106582
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and comparative study of rapid detection methods for Salmonella based on multiple molecular and immunological techniques

Jifu Ma, Xingmei Deng, Wei Zhang, Xia Zhou et al.
International Dairy Journal
Biosensors and Analytical Detection
article

Development and comparative study of rapid detection methods for Salmonella based on multiple molecular and immunological techniques

Jifu Ma, Xingmei Deng, Wei Zhang, Xia Zhou, Haitao Zhang, Yue Yang, Tianyi Zhao, Zhen Wang, Qian Zhang, Feifan Liu, Changan Chen, Zhihua Sun, Jia Guo
article en

Abstract

The detection of Salmonella in milk is critical for dairy safety, requiring rapid and sensitive methods. This study developed and compared three independent techniques: real-time PCR (qPCR), loop-mediated isothermal amplification (LAMP), and a gold immunochromatographic test strip (GICT), all targeting the invA gene. In artificially contaminated milk, qPCR achieved a detection limit of 10 3 CFU/mL with no cross-reactivity against non-target bacteria. LAMP amplification was completed within 30 min at 63°C, with detection limits of 4.17×10 3 CFU/mL (visual) and 4.17×10 2 CFU/mL (gel electrophoresis). The GICT strip, based on monoclonal antibody 8E7 1C8, showed a detection limit of 10 4 CFU/mL and remained stable for six months at 4°C. While qPCR and LAMP offered high sensitivity suitable for laboratory quantification, GICT provided a rapid, equipment-free option for on-site screening. Together, these methods provide a complementary toolkit for detecting Salmonella across laboratory and field settings.

International Dairy JournalVol. 177
Shihezi University (CN), Xinjiang Production and Construction Corps (CN), Animal Science Research Institute (CN), Xinjiang Academy of Agricultural and Reclamation Science (CN), Yangzhou University (CN)
Openalex Percentile: Top 57%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and comparative study of rapid detection methods for Salmonella based on multiple molecular and immunological techniques — Jifu Ma, Xingmei Deng, et al. · International Dairy Journal (2026) | TGRS Research Map | TGRS