<scp>icBTnC2</scp> , a new green calcium indicator based on troponin C and <scp>mBaoJin</scp> , with enhanced photostability

Genetically encoded green calcium indicators (GECIs) are broadly used for visualizing calcium transients in living cells. Among the diverse family of green GECIs, the Troponin C-based family offers potential advantages, including reduced calcium buffering, smaller molecular size, linear calcium response, and low cytotoxicity. However, the Troponin C-based GECIs with inverted calcium response are less developed compared to other popular GECIs, including GCaMPs and GECOs, and, as a consequence, have several drawbacks related to low dynamic range, brightness, photostability, and calcium ion sensitivity. To address these limitations, we developed a novel GECI, called icBTnC2, which incorporates Troponin C as a sensing moiety and the new bright photostable green FP mBaoJin as a reporting moiety. icBTnC2 demonstrated an inverted fluorescent response to calcium ion binding with a K<sub>d</sub> of 62 nM. In terms of fluorescence contrast and calcium ion affinity in vitro, icBTnC2 was comparable to the best widely used calmodulin-based GECIs from the GCaMP family. icBTnC2 demonstrated superior photostability under wide-field fluorescence microscopy exhibiting 5.5-, 4.8-, 3.2-, 2.9-, and 1.3-fold higher photobleaching half-time compared to iYTnC2, mEGFP, NCaMP7, jGCaMP8f, and mBaoJin, respectively. The icBTnC2 indicator was benchmarked against other GECIs, such as jGCaMP8f, NCaMP7, iYTnC2, and R-GECO1, for visualization of calcium transients in mammalian cells and primary neuron cultures, and tested for calcium-dependent changes in fluorescence lifetime. Finally, we solved the crystal structure of the icBTnC2 indicator at 1.55 Å resolution in the calcium-bound state and, using directed mutagenesis, proposed the molecular basis of its fluorescent response to calcium ion binding.

Authors

Institutions

Publication Details

Journal
Protein Science
Published
2026-02-13
DOI
https://doi.org/10.1002/pro.70499
Citations
1
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
16.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

icBTnC2 , a new green calcium indicator based on troponin C and mBaoJin , with enhanced photostability

Anastasia N. Romantsova, Kiryl D. Piatkevich, A. V. Vlaskina, Shihao Zhou et al.
1 citations
Protein Science
Molecular Sensors and Ion Detection
16.26
article

icBTnC2 , a new green calcium indicator based on troponin C and mBaoJin , with enhanced photostability

Anastasia N. Romantsova, Kiryl D. Piatkevich, A. V. Vlaskina, Shihao Zhou, Fedor V. Subach, Vladimir O. Popov, Павел В. Дороватовский, A.Y. Nikolaeva, Gleb D. Lesnov, Konstantin M. Boyko, Yulia K. Agapova, Dmitriy E. Petrenko, Sofia A. Chelykhova, Oksana M. Subach
article en
1 citations

Abstract

Genetically encoded green calcium indicators (GECIs) are broadly used for visualizing calcium transients in living cells. Among the diverse family of green GECIs, the Troponin C-based family offers potential advantages, including reduced calcium buffering, smaller molecular size, linear calcium response, and low cytotoxicity. However, the Troponin C-based GECIs with inverted calcium response are less developed compared to other popular GECIs, including GCaMPs and GECOs, and, as a consequence, have several drawbacks related to low dynamic range, brightness, photostability, and calcium ion sensitivity. To address these limitations, we developed a novel GECI, called icBTnC2, which incorporates Troponin C as a sensing moiety and the new bright photostable green FP mBaoJin as a reporting moiety. icBTnC2 demonstrated an inverted fluorescent response to calcium ion binding with a K<sub>d</sub> of 62 nM. In terms of fluorescence contrast and calcium ion affinity in vitro, icBTnC2 was comparable to the best widely used calmodulin-based GECIs from the GCaMP family. icBTnC2 demonstrated superior photostability under wide-field fluorescence microscopy exhibiting 5.5-, 4.8-, 3.2-, 2.9-, and 1.3-fold higher photobleaching half-time compared to iYTnC2, mEGFP, NCaMP7, jGCaMP8f, and mBaoJin, respectively. The icBTnC2 indicator was benchmarked against other GECIs, such as jGCaMP8f, NCaMP7, iYTnC2, and R-GECO1, for visualization of calcium transients in mammalian cells and primary neuron cultures, and tested for calcium-dependent changes in fluorescence lifetime. Finally, we solved the crystal structure of the icBTnC2 indicator at 1.55 Å resolution in the calcium-bound state and, using directed mutagenesis, proposed the molecular basis of its fluorescent response to calcium ion binding.

Protein ScienceVol. 35(3)
Kurchatov Institute (RU), Westlake University (CN), A N Bach Institute of Biochemistry (RU), Institute for Advanced Study (DE)
Openalex Percentile: Top 1%
Molecular Sensors and Ion Detection
16.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.