Separation estimation of two freely rotating dipole emitters near the quantum limit

According to Rayleigh's criterion, two incoherent emitters with a separation below the diffraction limit are not resolvable with a conventional fluorescence microscope. One method of superresolution microscopy (SRM) circumvents the diffraction-limited resolution by precisely estimating the position of spatiotemporally independent emitters. However, these methods of SRM techniques are not optimal for estimating the separation of two simultaneously excited emitters. Recently, a number of detection methods based on modal imaging have been developed to achieve the quantum Cramér-Rao lower bound (QCRB) to estimate the separations between two nearby emitters. The QCRB determines the minimum achievable precision for all possible detection methods. Current modal imaging techniques assume a scalar field generated from a point source, such as a distant source from an optical fiber or a pinhole. However, for fluorescently labeled samples, point emitters are single fluorophores that are modeled as dipole emitters and, in practice, are often freely rotating. Dipole radiation must be described by vectorial theory, and the assumption of a scalar field no longer holds. Here, we present a method to numerically calculate the QCRB for measuring the separation of two dipole emitters, incorporating the vectorial theory. Furthermore, we propose a near-quantum optimal detection scheme based on one of the modal imaging techniques, superlocalization by image inversion interferometry (SLIVER), for estimating the separation of two freely rotating dipoles. In the proposed method, we introduce a vortex wave plate before the SLIVER detection to separate the radial and azimuthal components of the dipole radiation. With numerical simulations, we demonstrated that our method achieves nondivergent precision at any separation between two dipole emitters. We investigated several practical effects relevant to experimental measurements in superresolution microscopy, including numerical aperture, detection bandwidth, number of estimation parameters, background, and misalignment on separation estimation. Our proposed measurement provides a near-quantum-limited detection scheme for measuring the separation of two freely rotating dipole emitters, such as fluorescently tagged molecules, which are commonly used in superresolution microscopy.

Authors

Institutions

Publication Details

Journal
Physical review. A/Physical review, A
Published
2026-02-13
DOI
https://doi.org/10.1103/nwrq-4fqv
Primary Topic
Quantum Information and Cryptography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Separation estimation of two freely rotating dipole emitters near the quantum limit

Keith A. Lidke, Sujeet Pani, F. E. Becerra, Sajjad A. Khan
Physical review. A/Physical review, A
Quantum Information and Cryptography
article

Separation estimation of two freely rotating dipole emitters near the quantum limit

Keith A. Lidke, Sujeet Pani, F. E. Becerra, Sajjad A. Khan
article en

Abstract

According to Rayleigh's criterion, two incoherent emitters with a separation below the diffraction limit are not resolvable with a conventional fluorescence microscope. One method of superresolution microscopy (SRM) circumvents the diffraction-limited resolution by precisely estimating the position of spatiotemporally independent emitters. However, these methods of SRM techniques are not optimal for estimating the separation of two simultaneously excited emitters. Recently, a number of detection methods based on modal imaging have been developed to achieve the quantum Cramér-Rao lower bound (QCRB) to estimate the separations between two nearby emitters. The QCRB determines the minimum achievable precision for all possible detection methods. Current modal imaging techniques assume a scalar field generated from a point source, such as a distant source from an optical fiber or a pinhole. However, for fluorescently labeled samples, point emitters are single fluorophores that are modeled as dipole emitters and, in practice, are often freely rotating. Dipole radiation must be described by vectorial theory, and the assumption of a scalar field no longer holds. Here, we present a method to numerically calculate the QCRB for measuring the separation of two dipole emitters, incorporating the vectorial theory. Furthermore, we propose a near-quantum optimal detection scheme based on one of the modal imaging techniques, superlocalization by image inversion interferometry (SLIVER), for estimating the separation of two freely rotating dipoles. In the proposed method, we introduce a vortex wave plate before the SLIVER detection to separate the radial and azimuthal components of the dipole radiation. With numerical simulations, we demonstrated that our method achieves nondivergent precision at any separation between two dipole emitters. We investigated several practical effects relevant to experimental measurements in superresolution microscopy, including numerical aperture, detection bandwidth, number of estimation parameters, background, and misalignment on separation estimation. Our proposed measurement provides a near-quantum-limited detection scheme for measuring the separation of two freely rotating dipole emitters, such as fluorescently tagged molecules, which are commonly used in superresolution microscopy.

Physical review. A/Physical review, AVol. 113(3)
Clemson University (US)
Openalex Percentile: Top 58%
Quantum Information and Cryptography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.