Optical path coupling optimization analysis of compact flat circular multi-pass cell for hydrogen leakage laser absorption spectroscopy detection

Ensuring reliable hydrogen monitoring is vital to the safety of fuel cell systems, particularly when operation takes place in confined spaces. Conventional detection methods are often limited by optical loss, insufficient sensitivity, and delayed response. To overcome these limitations, we design a miniaturized flat circular multi-pass cell that maximizes optical path length and irradiance utilization while maintaining a small chamber volume. The configuration consists of a planar reflector array combined with a semi-closed housing, where a microporous cover promotes stable and uniform gas exchange. With optimized incident and reflection angles, the beam traces a spiral two-layer trajectory, yielding a total optical path of 1.54 m inside a cell of only 18.85 ml. A comparative study of polygonal reflection layouts identifies the 20-spike geometry as the most efficient compromise between structural complexity and optical efficiency, leading to merely 8.743% signal attenuation after multiple reflections. Unlike traditional spherical or parabolic mirror cells, this design not only suppresses loss effectively but also enhances average irradiance by nearly threefold. The tolerance analysis of the model is carried out to ensure that the beam propagates stably in the cell without deviation. Simulation further reveals that increasing beam divergence from 0.03° to 0.075° enlarges the spot size and aggravates optical loss. Owing to its compactness and reduced energy dissipation, the proposed structure enables direct in situ hydrogen detection within fuel cells, providing improved spatial efficiency and faster measurement response.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2026-02-01
DOI
https://doi.org/10.1063/5.0304197
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical path coupling optimization analysis of compact flat circular multi-pass cell for hydrogen leakage laser absorption spectroscopy detection

Wenxing Chen, Tao Chen, X L Liao, Zhenyu Wu et al.
Review of Scientific Instruments
Spectroscopy and Laser Applications
article

Optical path coupling optimization analysis of compact flat circular multi-pass cell for hydrogen leakage laser absorption spectroscopy detection

Wenxing Chen, Tao Chen, X L Liao, Zhenyu Wu, Wei Zhou, Di Wang, Tianyang Cong, Yan Lv, Yanlei Liu
article en

Abstract

Ensuring reliable hydrogen monitoring is vital to the safety of fuel cell systems, particularly when operation takes place in confined spaces. Conventional detection methods are often limited by optical loss, insufficient sensitivity, and delayed response. To overcome these limitations, we design a miniaturized flat circular multi-pass cell that maximizes optical path length and irradiance utilization while maintaining a small chamber volume. The configuration consists of a planar reflector array combined with a semi-closed housing, where a microporous cover promotes stable and uniform gas exchange. With optimized incident and reflection angles, the beam traces a spiral two-layer trajectory, yielding a total optical path of 1.54 m inside a cell of only 18.85 ml. A comparative study of polygonal reflection layouts identifies the 20-spike geometry as the most efficient compromise between structural complexity and optical efficiency, leading to merely 8.743% signal attenuation after multiple reflections. Unlike traditional spherical or parabolic mirror cells, this design not only suppresses loss effectively but also enhances average irradiance by nearly threefold. The tolerance analysis of the model is carried out to ensure that the beam propagates stably in the cell without deviation. Simulation further reveals that increasing beam divergence from 0.03° to 0.075° enlarges the spot size and aggravates optical loss. Owing to its compactness and reduced energy dissipation, the proposed structure enables direct in situ hydrogen detection within fuel cells, providing improved spatial efficiency and faster measurement response.

Review of Scientific InstrumentsVol. 97(2)
Daqing Oilfield General Hospital (CN), Hangzhou Special Equipment Inspection and Research Institute (CN), Northeast Petroleum University (CN)
Affordable and clean energy
Openalex Percentile: Top 58%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.