In vitro and in vivo validation of a novel 3D-printed vessel anastomosis device for microvascular surgery

Microvascular anastomosis is fundamental to free-flap reconstruction, yet hand-sutured techniques remain highly skill-dependent and prolong ischemic time, contributing to thrombosis and flap loss. Current suture-less devices accelerate anastomosis but are constrained by vessel-size mismatch, eversion-related intimal injury, and inconsistent arterial performance. A clinically adaptable, arterial-capable system is needed. We developed a customizable, 3D-printed intraluminal coupler with a snap-fit connection and elastic external clasp that avoids vessel eversion and preserves length. Devices were fabricated via SLA or PolyJet printing using clinically used resins. Benchtop evaluation included burst-pressure testing, tensile testing, wettability and endothelial cytocompatibility assays with oxygen-plasma surface modification. Deployment was assessed ex vivo using porcine coronary vessels and in vivo in a porcine carotid arterial model with patency monitoring over 4 h. Couplers sustained leakage pressures of ~ 90 mmHg vs. ~16 mmHg for hand-sutured controls (P < 0.01), while maintaining comparable mechanical strength (≈ 2–3 N). Plasma surface treatment reduced water contact angles (≈ 85°→≈60°) and tripled endothelial attachment, restoring confluent morphology. Ex vivo deployment achieved completion in 9.47 ± 1.20 min, a ~ 62.5% reduction vs. published suturing times. In vivo, couplers restored immediate perfusion with no leakage or thrombosis. This 3D-printed intraluminal coupler demonstrates mechanical feasibility, rapid deploy-ability, and surface-modifiable endothelial compatibility in benchtop and short-term large-animal feasibility testing, supporting its potential for further preclinical development as a vascular anastomosis technology. Future survival studies and anti-thrombogenic surface engineering will advance readiness for clinical implementation.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-13
DOI
https://doi.org/10.1038/s41598-026-39181-4
Primary Topic
Reconstructive Surgery and Microvascular Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vitro and in vivo validation of a novel 3D-printed vessel anastomosis device for microvascular surgery

Lars Rasmusson, John Ser Pheng Loh, Kuan-Che Feng, Justin Kok Soon Tan et al.
Scientific Reports
Reconstructive Surgery and Microvascular Techniques
article

In vitro and in vivo validation of a novel 3D-printed vessel anastomosis device for microvascular surgery

Lars Rasmusson, John Ser Pheng Loh, Kuan-Che Feng, Justin Kok Soon Tan, Yijia Yuan, Yinling Zhu, Hwa Liang Leo, Robert Heymann
article en

Abstract

Microvascular anastomosis is fundamental to free-flap reconstruction, yet hand-sutured techniques remain highly skill-dependent and prolong ischemic time, contributing to thrombosis and flap loss. Current suture-less devices accelerate anastomosis but are constrained by vessel-size mismatch, eversion-related intimal injury, and inconsistent arterial performance. A clinically adaptable, arterial-capable system is needed. We developed a customizable, 3D-printed intraluminal coupler with a snap-fit connection and elastic external clasp that avoids vessel eversion and preserves length. Devices were fabricated via SLA or PolyJet printing using clinically used resins. Benchtop evaluation included burst-pressure testing, tensile testing, wettability and endothelial cytocompatibility assays with oxygen-plasma surface modification. Deployment was assessed ex vivo using porcine coronary vessels and in vivo in a porcine carotid arterial model with patency monitoring over 4 h. Couplers sustained leakage pressures of ~ 90 mmHg vs. ~16 mmHg for hand-sutured controls (P < 0.01), while maintaining comparable mechanical strength (≈ 2–3 N). Plasma surface treatment reduced water contact angles (≈ 85°→≈60°) and tripled endothelial attachment, restoring confluent morphology. Ex vivo deployment achieved completion in 9.47 ± 1.20 min, a ~ 62.5% reduction vs. published suturing times. In vivo, couplers restored immediate perfusion with no leakage or thrombosis. This 3D-printed intraluminal coupler demonstrates mechanical feasibility, rapid deploy-ability, and surface-modifiable endothelial compatibility in benchtop and short-term large-animal feasibility testing, supporting its potential for further preclinical development as a vascular anastomosis technology. Future survival studies and anti-thrombogenic surface engineering will advance readiness for clinical implementation.

Scientific ReportsVol. 16(1)
Karolinska University Hospital (SE), National University of Singapore (SG), Karolinska Institutet (SE), University of Gothenburg (SE), KU Leuven (BE)
National University of Singapore
Openalex Percentile: Top 57%
Reconstructive Surgery and Microvascular Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.