Implementation of Sterilization and Disinfection Protocols for Potentiometric Microneedle Sensors: A Requirement for a Safety Assertion

Microneedle (MN) sensors represent a promising technology for disease surveillance. For their application in long-term animal studies and preclinical research, they must exhibit both analytical reliability and biosafety, including the elimination of microorganisms capable of inducing infection. Nonetheless, MNs' compatibility with conventional sterilization and disinfection methods remains largely unexplored. Accordingly, we introduce the first systematic evaluation of the compatibility of potentiometric MN sensors with sterilization and high-level disinfection protocols widely available in laboratory settings, including ethanol, autoclave, and UV-C exposure. As a proof-of-concept, we assess the impact of these three protocols on the analytical performance of a complete potentiometric cell in the MN configuration (i.e., pH-MN based on tridodecylamine as hydrogen ionophore and polyurethane as polymer matrix and polyvinyl butyral-Ag/AgCl reference electrode MN). Ethanol treatment preserved the calibration parameters of the sensor, maintaining a near-Nernstian response even after prolonged exposure (30 min), with minimal change in the slope (58.9 vs 57.9 mV pH<sup>-1</sup>). Slight variations were observed in the standard potential (<i>E</i><sup>0</sup>), although all differences remained below 5%. In contrast, autoclaving severely compromised both MN electrodes, confirming incompatibility with our pH-MN design. Then, UV-C was further optimized through a two-step exposure protocol, resulting in the maintenance of the sensor accuracy with <4% deviation from a reference pH value. After confirming analytical reliability, microbiological assays were conducted to evaluate the microbial inactivation effectiveness of ethanol and UV-C protocols. Both treatments successfully eliminated bacterial contamination even in sensors with a high level of contamination, supporting their suitability for preclinical use. Finally, both protocols were validated for intradermal pH sensing in <i>ex vivo</i> skin, showing excellent agreement (<4% deviation) with a commercial pH electrode. Overall, we present a systematic validation workflow to assess disinfection and sterilization method compatibility with polymer-membrane ion-selective microneedle patches. The workflow can provide a basis for designing analogous tests for other microneedle-based potentiometric sensors and potentially also in other sensing principles.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2026-02-13
DOI
https://doi.org/10.1021/acssensors.5c04039
Citations
1
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
27.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of Sterilization and Disinfection Protocols for Potentiometric Microneedle Sensors: A Requirement for a Safety Assertion

Gastón A. Crespo, María Cuartero, Yuxin Chen, Ruben Zapata-Pérez et al.
1 citations
ACS Sensors
Advancements in Transdermal Drug Delivery
27.80
article

Implementation of Sterilization and Disinfection Protocols for Potentiometric Microneedle Sensors: A Requirement for a Safety Assertion

Gastón A. Crespo, María Cuartero, Yuxin Chen, Ruben Zapata-Pérez, Agueda Molinero-Fernandez, Xue Hui
article en
1 citations

Abstract

Microneedle (MN) sensors represent a promising technology for disease surveillance. For their application in long-term animal studies and preclinical research, they must exhibit both analytical reliability and biosafety, including the elimination of microorganisms capable of inducing infection. Nonetheless, MNs' compatibility with conventional sterilization and disinfection methods remains largely unexplored. Accordingly, we introduce the first systematic evaluation of the compatibility of potentiometric MN sensors with sterilization and high-level disinfection protocols widely available in laboratory settings, including ethanol, autoclave, and UV-C exposure. As a proof-of-concept, we assess the impact of these three protocols on the analytical performance of a complete potentiometric cell in the MN configuration (i.e., pH-MN based on tridodecylamine as hydrogen ionophore and polyurethane as polymer matrix and polyvinyl butyral-Ag/AgCl reference electrode MN). Ethanol treatment preserved the calibration parameters of the sensor, maintaining a near-Nernstian response even after prolonged exposure (30 min), with minimal change in the slope (58.9 vs 57.9 mV pH<sup>-1</sup>). Slight variations were observed in the standard potential (<i>E</i><sup>0</sup>), although all differences remained below 5%. In contrast, autoclaving severely compromised both MN electrodes, confirming incompatibility with our pH-MN design. Then, UV-C was further optimized through a two-step exposure protocol, resulting in the maintenance of the sensor accuracy with <4% deviation from a reference pH value. After confirming analytical reliability, microbiological assays were conducted to evaluate the microbial inactivation effectiveness of ethanol and UV-C protocols. Both treatments successfully eliminated bacterial contamination even in sensors with a high level of contamination, supporting their suitability for preclinical use. Finally, both protocols were validated for intradermal pH sensing in <i>ex vivo</i> skin, showing excellent agreement (<4% deviation) with a commercial pH electrode. Overall, we present a systematic validation workflow to assess disinfection and sterilization method compatibility with polymer-membrane ion-selective microneedle patches. The workflow can provide a basis for designing analogous tests for other microneedle-based potentiometric sensors and potentially also in other sensing principles.

ACS Sensors
Universidad Católica de Murcia (ES), KTH Royal Institute of Technology (SE)
Openalex Percentile: Top 1%
Advancements in Transdermal Drug Delivery
27.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.