Measurements of the Distribution of Ionization Losses Along the Track of a $${}^{{210}}$$Pb Recoil Nucleus Using a Matrix End-Cap Proportional Counter

The paper presents the results of measuring the distribution of ionization losses along the track of a recoil nucleus ( $${}^{210}$$ Pb) with an initial energy of 146.5 keV from the decay of $${}^{214}$$ Po. The measurements were carried out using a multi-cell matrix ( $$3\times 3$$ ) end-cap proportional counter (MCPC). Each cell is an end-face proportional counter $$d=5$$ mm with a ring anode $$d=0.7$$ mm. The MTPC was filled with a mixture of $$96.3\%\textrm{Ar}+3.7\%\textrm{Xe}$$ at a pressure of 62 Torr. Recoil nuclei were emitted from the source surface in the central part of the drift electrode. The sour electric field of daughter products of $${}^{222}$$ Rn decay from an auxiliary xenon carrier gas. Calibration was carried out using the energy releases of $$\alpha$$ -particles from the same source at a distance between the drift electrode and the recording plane. It was determined that the amplitude of pulses from recoil nuclei at the peak of the spectrum corresponds to an energy of $$63.1\pm 2.9$$ keV.

Authors

Institutions

Publication Details

Journal
Physics of Atomic Nuclei
Published
2025-12-01
DOI
https://doi.org/10.1134/s1063778825601970
Primary Topic
Radioactive Decay and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurements of the Distribution of Ionization Losses Along the Track of a $${}^{{210}}$$Pb Recoil Nucleus Using a Matrix End-Cap Proportional Counter

A. M. Gezhaev, A. M. Gangapshev, V. V. Kuzminov, R. A. Etezov et al.
Physics of Atomic Nuclei
Radioactive Decay and Measurement Techniques
article

Measurements of the Distribution of Ionization Losses Along the Track of a $${}^{{210}}$$Pb Recoil Nucleus Using a Matrix End-Cap Proportional Counter

A. M. Gezhaev, A. M. Gangapshev, V. V. Kuzminov, R. A. Etezov, V. V. Kazalov
article en

Abstract

The paper presents the results of measuring the distribution of ionization losses along the track of a recoil nucleus ( $${}^{210}$$ Pb) with an initial energy of 146.5 keV from the decay of $${}^{214}$$ Po. The measurements were carried out using a multi-cell matrix ( $$3\times 3$$ ) end-cap proportional counter (MCPC). Each cell is an end-face proportional counter $$d=5$$ mm with a ring anode $$d=0.7$$ mm. The MTPC was filled with a mixture of $$96.3\%\textrm{Ar}+3.7\%\textrm{Xe}$$ at a pressure of 62 Torr. Recoil nuclei were emitted from the source surface in the central part of the drift electrode. The sour electric field of daughter products of $${}^{222}$$ Rn decay from an auxiliary xenon carrier gas. Calibration was carried out using the energy releases of $$\alpha$$ -particles from the same source at a distance between the drift electrode and the recording plane. It was determined that the amplitude of pulses from recoil nuclei at the peak of the spectrum corresponds to an energy of $$63.1\pm 2.9$$ keV.

Physics of Atomic NucleiVol. 88(6)
Kabardino-Balkarian State University (RU), Institute for Nuclear Research (RU), National Research Nuclear University MEPhI (RU)
Affordable and clean energy
Openalex Percentile: Top 23%
Radioactive Decay and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.