Microtensile Bond Strength and Microhardness of Resin–dentin Bonds using Different Resin-based Composite Systems

Introduction Dental caries remain a major global health concern, emphasizing the need for durable restorative materials with reliable mechanical properties. This study aimed to compare the μTBS and Vickers hardness number (VHN) of three composite materials (3M Filtek Z250, Kerr OptiShade, and SHOFU Beautifil II LS) on sound coronal dentin using a corresponding bonding system (3M Universal Bond, Kerr OptiBond, and SHOFU BeautiBond Universal Adhesive, respectively). Methods Dentin surfaces were exposed from twelve extracted molars. Each composite and its respective adhesive were applied and cured. The teeth were cut into 1 × 1 × 8 mm beams. Twenty beams per group were tested for μTBS. Additionally, 20 composite discs (2 x 10 mm) were prepared for each material. VHN was measured at three sites per disc, and mean values were calculated. Results Filtek Z250 showed the highest VHN, followed by OptiShade and Beautifil II LS, with significant differences among all groups. OptiShade demonstrated the highest μTBS, followed by Filtek Z250 and Beautifil II LS. μTBS differed significantly between Beautifil II LS and both Filtek Z250 and OptiShade but not between Filtek Z250 and OptiShade. Discussion Differences in filler composition, resin matrix characteristics, and adhesive protocols likely contributed to the variations observed in microhardness, bonding performance, and restoration longevity. Conclusions Filtek Z250 exhibited superior microhardness, while OptiShade demonstrated superior bond strength. Beautifil II LS performed the worst in both tests. These findings support evidence-based material selection to enhance restoration longevity.

Authors

Institutions

Publication Details

Journal
The Open Dentistry Journal
Published
2026-02-13
DOI
https://doi.org/10.2174/0118742106417353260210092303
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microtensile Bond Strength and Microhardness of Resin–dentin Bonds using Different Resin-based Composite Systems

Hammam Ahmed Bahammam, Salma Ghazi Alharbi, Bassam Naoraldean Zidane, Dana Hashem Alhebshi
The Open Dentistry Journal
Dental materials and restorations
article

Microtensile Bond Strength and Microhardness of Resin–dentin Bonds using Different Resin-based Composite Systems

Hammam Ahmed Bahammam, Salma Ghazi Alharbi, Bassam Naoraldean Zidane, Dana Hashem Alhebshi
article en

Abstract

Introduction Dental caries remain a major global health concern, emphasizing the need for durable restorative materials with reliable mechanical properties. This study aimed to compare the μTBS and Vickers hardness number (VHN) of three composite materials (3M Filtek Z250, Kerr OptiShade, and SHOFU Beautifil II LS) on sound coronal dentin using a corresponding bonding system (3M Universal Bond, Kerr OptiBond, and SHOFU BeautiBond Universal Adhesive, respectively). Methods Dentin surfaces were exposed from twelve extracted molars. Each composite and its respective adhesive were applied and cured. The teeth were cut into 1 × 1 × 8 mm beams. Twenty beams per group were tested for μTBS. Additionally, 20 composite discs (2 x 10 mm) were prepared for each material. VHN was measured at three sites per disc, and mean values were calculated. Results Filtek Z250 showed the highest VHN, followed by OptiShade and Beautifil II LS, with significant differences among all groups. OptiShade demonstrated the highest μTBS, followed by Filtek Z250 and Beautifil II LS. μTBS differed significantly between Beautifil II LS and both Filtek Z250 and OptiShade but not between Filtek Z250 and OptiShade. Discussion Differences in filler composition, resin matrix characteristics, and adhesive protocols likely contributed to the variations observed in microhardness, bonding performance, and restoration longevity. Conclusions Filtek Z250 exhibited superior microhardness, while OptiShade demonstrated superior bond strength. Beautifil II LS performed the worst in both tests. These findings support evidence-based material selection to enhance restoration longevity.

The Open Dentistry JournalVol. 20(1)
Yanbu University College (SA), King Abdulaziz University (SA), King Fahad Hospital Jeddah (SA)
Openalex Percentile: Top 56%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.