Dynamic calibration of the air-bearing table for the swing arm profilometer test

The swing arm profilometer (SAP) has great potential to achieve high-accuracy measurements for large-aperture optic surfaces. To promote the precision of the SAP further, we proposed a dynamic calibration setup with four high-accuracy capacitive probes and a standard circular ring flat to monitor error motions of the air-bearing table of the SAP during surface measurement. We implemented an experiment on a <i>∅</i>400 mm flat and achieved an accuracy of 15 nm. Compared with the traditional SAP test results, the accuracy was improved by 25%. Experimenting on a <i>∅</i>2000 mm off-axis aspheric surface displayed that the ring-shaped system errors from the SAP test were eliminated with a 12% improvement in accuracy. It exhibited a good suppression effect on rotationally symmetric errors from the SAP.

Authors

Institutions

Publication Details

Journal
Applied Optics
Published
2026-02-13
DOI
https://doi.org/10.1364/ao.585050
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic calibration of the air-bearing table for the swing arm profilometer test

Ling Xiong, Xiao Luo, Xuejun Zhang, Hao Chen et al.
Applied Optics
Optical measurement and interference techniques
article

Dynamic calibration of the air-bearing table for the swing arm profilometer test

Ling Xiong, Xiao Luo, Xuejun Zhang, Hao Chen, zhenyu liu, Qiang Cheng, Haixiang Hu, Feng Zhang
article en

Abstract

The swing arm profilometer (SAP) has great potential to achieve high-accuracy measurements for large-aperture optic surfaces. To promote the precision of the SAP further, we proposed a dynamic calibration setup with four high-accuracy capacitive probes and a standard circular ring flat to monitor error motions of the air-bearing table of the SAP during surface measurement. We implemented an experiment on a <i>∅</i>400 mm flat and achieved an accuracy of 15 nm. Compared with the traditional SAP test results, the accuracy was improved by 25%. Experimenting on a <i>∅</i>2000 mm off-axis aspheric surface displayed that the ring-shaped system errors from the SAP test were eliminated with a 12% improvement in accuracy. It exhibited a good suppression effect on rotationally symmetric errors from the SAP.

Applied OpticsVol. 65(8)
Chinese Academy of Sciences (CN), Advanced Optical Systems (United States) (US)
Affordable and clean energy
Openalex Percentile: Top 57%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.