Dynamic calibration of the air-bearing table for the swing arm profilometer test
The swing arm profilometer (SAP) has great potential to achieve high-accuracy measurements for large-aperture optic surfaces. To promote the precision of the SAP further, we proposed a dynamic calibration setup with four high-accuracy capacitive probes and a standard circular ring flat to monitor error motions of the air-bearing table of the SAP during surface measurement. We implemented an experiment on a <i>∅</i>400 mm flat and achieved an accuracy of 15 nm. Compared with the traditional SAP test results, the accuracy was improved by 25%. Experimenting on a <i>∅</i>2000 mm off-axis aspheric surface displayed that the ring-shaped system errors from the SAP test were eliminated with a 12% improvement in accuracy. It exhibited a good suppression effect on rotationally symmetric errors from the SAP.
Authors
- Ling Xiong (ORCID: https://orcid.org/0000-0002-2359-429X)
- Xiao Luo
- Xuejun Zhang
- Hao Chen
- zhenyu liu
- Qiang Cheng
- Haixiang Hu
- Feng Zhang
Institutions
- Chinese Academy of Sciences (CN)
- Advanced Optical Systems (United States) (US)
Publication Details
- Journal
- Applied Optics
- Published
- 2026-02-13
- DOI
- https://doi.org/10.1364/ao.585050
- Primary Topic
- Optical measurement and interference techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.00