A modified broad beam model for uniformly scanned carbon ion therapy accounting for field inhomogeneities

The purpose was to perform beam modeling and plan verification for uniform scanned (US) carbon ion therapy delivered by Heavy Ion Medical Machine (HIMM). As the field inhomogeneity is larger than the commonly accepted 3% gamma pass rate criteria, a simple flat broad beam model is no longer accurate. A modified broad beam model accounting for field inhomogeneity was proposed and validated. The commissioning process for automatic beam modeling was described. Characteristic lateral dose distributions were collected at different depths for each field combination. The field inhomogeneities were modeled as two-dimensional interpolations of the lateral dose data. Dose calculation was based on ray-tracing combined with an asymmetric double-sigmoid function describing the dose at field edge. Two types of plan verifications on three US nozzles were carried out: 1) without range compensators 2) with range compensators. The distance-to-agreement at distal fall-off was within 1 mm. The absolute dose calibration was within 1.9% and the mean value was 0.6 (±0.5%). The verification plans satisfied 95% pass rate based on 3mm/3% gamma analysis for all three nozzles. Comparison with literature suggested a clinical factor of 1.33. The modified broad beam model satisfied the gamma analysis requirement and could be used for commissioning carbon US beams.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-13
DOI
https://doi.org/10.1038/s41598-026-39619-9
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A modified broad beam model for uniformly scanned carbon ion therapy accounting for field inhomogeneities

Yunzhou Xia
Scientific Reports
Radiation Therapy and Dosimetry
article

A modified broad beam model for uniformly scanned carbon ion therapy accounting for field inhomogeneities

Yunzhou Xia
article en

Abstract

The purpose was to perform beam modeling and plan verification for uniform scanned (US) carbon ion therapy delivered by Heavy Ion Medical Machine (HIMM). As the field inhomogeneity is larger than the commonly accepted 3% gamma pass rate criteria, a simple flat broad beam model is no longer accurate. A modified broad beam model accounting for field inhomogeneity was proposed and validated. The commissioning process for automatic beam modeling was described. Characteristic lateral dose distributions were collected at different depths for each field combination. The field inhomogeneities were modeled as two-dimensional interpolations of the lateral dose data. Dose calculation was based on ray-tracing combined with an asymmetric double-sigmoid function describing the dose at field edge. Two types of plan verifications on three US nozzles were carried out: 1) without range compensators 2) with range compensators. The distance-to-agreement at distal fall-off was within 1 mm. The absolute dose calibration was within 1.9% and the mean value was 0.6 (±0.5%). The verification plans satisfied 95% pass rate based on 3mm/3% gamma analysis for all three nozzles. Comparison with literature suggested a clinical factor of 1.33. The modified broad beam model satisfied the gamma analysis requirement and could be used for commissioning carbon US beams.

Scientific ReportsVol. 16(1)
China Academy of Chinese Medical Sciences (CN)
Openalex Percentile: Top 58%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.