The effect of pre-irradiation on deuterium retention and desorption behavior in tungsten and tungsten alloys

<bold>Background</bold>Tungsten (W) and tungsten alloys, such as 97W-2Ni-1Fe, are critical materials for nuclear fusion reactors due to their excellent thermal conductivity and high melting point. However, the performance of these materials can be significantly affected by irradiation-induced defects and deuterium (D) retention, which is crucial for maintaining material integrity and minimizing fuel retention in fusion environments.<bold>Purpose</bold>This study aims to investigate the influence of pre-irradiation defects on deuterium retention and desorption behavior in W and tungsten-nickel-iron (W-Ni-Fe) alloys.<bold>Methods</bold>Firstly, pure W and 97W-2Ni-1Fe alloy samples were irradiated with Fe<sup>13+</sup> ions at doses of 5×10<sup>14</sup> Fe·cm<sup>-2</sup> and 3×10<sup>15</sup> Fe·cm<sup>-2</sup> using the heavy ion accelerator at Lanzhou University, and SRIM simulations were conducted to model the defect and Fe ion distribution in the samples. Subsequently, D plasma irradiation was performed at Hefei University of Technology for 1 h at a constant plasma flow of 4×10<sup>16</sup> D·cm<sup>-2</sup> with 50 eV. Finally, the D retention and desorption behaviors were studied using Thermal Desorption Spectroscopy (TDS), Doppler-broadening Spectroscopy (DBS) of Positron Annihilation, Transmission Electron Microscopy (TEM), and Scanning Electron Microscopy (SEM). SRIM simulations were also conducted to model the defect and D atom distributions in the materials.<bold>Results</bold>Observational findings show that Fe<sup>13+</sup> ion irradiation induces significant vacancy-type defects in both materials, with higher defect concentrations in pure W compared to the alloy. D retention is observed to be higher in pure W, with desorption occurring at approximately 250 °C and 700 °C. In contrast, the 97W-2Ni-1Fe alloy shows reduced D retention, with desorption peaks at 200 °C and 700 °C. The TDS results reveal that pure W retained 2~3 times more D than the alloy. Pre-irradiation with Fe<sup>13+</sup> ions further enhances D retention, especially in pure W. TEM analysis results confirm the formation of D bubbles in the defect regions, especially under high-dose irradiation. Compared to pure tungsten, the deuterium retention of the 97W-2Ni-1Fe alloy decreases by 65.0% and 55.8% under low and high dose pre-irradiation conditions, respectively.<bold>Conclusions</bold>The 97W-2Ni-1Fe alloy demonstrates superior performance in minimizing D retention, with significantly lower D desorption and reduced bubble formation compared to pure W, hence is a more favorable material for applications where minimizing D retention and associated damage is critical, such as in fusion reactors. The results highlight the importance of material composition and defect structure in controlling D behavior under irradiation and plasma conditions, offering valuable insights into the design of next-generation plasma-facing materials.

Authors

Publication Details

Journal
Nuclear Techniques
Published
2026-02-01
DOI
https://doi.org/10.3724/j.0253-3219.2026.hjs.49.250019
Primary Topic
Fusion materials and technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effect of pre-irradiation on deuterium retention and desorption behavior in tungsten and tungsten alloys

Haiyu Xue, Daqing Yuan, te Zhu, Laima Luo et al.
Nuclear Techniques
Fusion materials and technologies
article

The effect of pre-irradiation on deuterium retention and desorption behavior in tungsten and tungsten alloys

Haiyu Xue, Daqing Yuan, te Zhu, Laima Luo, Xingzhong CAO, Sheng Liu, Peng Zhang, Pinjing CHENG, Haibiao WU
article en

Abstract

<bold>Background</bold>Tungsten (W) and tungsten alloys, such as 97W-2Ni-1Fe, are critical materials for nuclear fusion reactors due to their excellent thermal conductivity and high melting point. However, the performance of these materials can be significantly affected by irradiation-induced defects and deuterium (D) retention, which is crucial for maintaining material integrity and minimizing fuel retention in fusion environments.<bold>Purpose</bold>This study aims to investigate the influence of pre-irradiation defects on deuterium retention and desorption behavior in W and tungsten-nickel-iron (W-Ni-Fe) alloys.<bold>Methods</bold>Firstly, pure W and 97W-2Ni-1Fe alloy samples were irradiated with Fe<sup>13+</sup> ions at doses of 5×10<sup>14</sup> Fe·cm<sup>-2</sup> and 3×10<sup>15</sup> Fe·cm<sup>-2</sup> using the heavy ion accelerator at Lanzhou University, and SRIM simulations were conducted to model the defect and Fe ion distribution in the samples. Subsequently, D plasma irradiation was performed at Hefei University of Technology for 1 h at a constant plasma flow of 4×10<sup>16</sup> D·cm<sup>-2</sup> with 50 eV. Finally, the D retention and desorption behaviors were studied using Thermal Desorption Spectroscopy (TDS), Doppler-broadening Spectroscopy (DBS) of Positron Annihilation, Transmission Electron Microscopy (TEM), and Scanning Electron Microscopy (SEM). SRIM simulations were also conducted to model the defect and D atom distributions in the materials.<bold>Results</bold>Observational findings show that Fe<sup>13+</sup> ion irradiation induces significant vacancy-type defects in both materials, with higher defect concentrations in pure W compared to the alloy. D retention is observed to be higher in pure W, with desorption occurring at approximately 250 °C and 700 °C. In contrast, the 97W-2Ni-1Fe alloy shows reduced D retention, with desorption peaks at 200 °C and 700 °C. The TDS results reveal that pure W retained 2~3 times more D than the alloy. Pre-irradiation with Fe<sup>13+</sup> ions further enhances D retention, especially in pure W. TEM analysis results confirm the formation of D bubbles in the defect regions, especially under high-dose irradiation. Compared to pure tungsten, the deuterium retention of the 97W-2Ni-1Fe alloy decreases by 65.0% and 55.8% under low and high dose pre-irradiation conditions, respectively.<bold>Conclusions</bold>The 97W-2Ni-1Fe alloy demonstrates superior performance in minimizing D retention, with significantly lower D desorption and reduced bubble formation compared to pure W, hence is a more favorable material for applications where minimizing D retention and associated damage is critical, such as in fusion reactors. The results highlight the importance of material composition and defect structure in controlling D behavior under irradiation and plasma conditions, offering valuable insights into the design of next-generation plasma-facing materials.

Nuclear TechniquesVol. 49(2)
National Natural Science Foundation of China, Chinese Academy of Sciences
Openalex Percentile: Top 58%
Fusion materials and technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.