The effect of pre-irradiation on deuterium retention and desorption behavior in tungsten and tungsten alloys
<bold>Background</bold>Tungsten (W) and tungsten alloys, such as 97W-2Ni-1Fe, are critical materials for nuclear fusion reactors due to their excellent thermal conductivity and high melting point. However, the performance of these materials can be significantly affected by irradiation-induced defects and deuterium (D) retention, which is crucial for maintaining material integrity and minimizing fuel retention in fusion environments.<bold>Purpose</bold>This study aims to investigate the influence of pre-irradiation defects on deuterium retention and desorption behavior in W and tungsten-nickel-iron (W-Ni-Fe) alloys.<bold>Methods</bold>Firstly, pure W and 97W-2Ni-1Fe alloy samples were irradiated with Fe<sup>13+</sup> ions at doses of 5×10<sup>14</sup> Fe·cm<sup>-2</sup> and 3×10<sup>15</sup> Fe·cm<sup>-2</sup> using the heavy ion accelerator at Lanzhou University, and SRIM simulations were conducted to model the defect and Fe ion distribution in the samples. Subsequently, D plasma irradiation was performed at Hefei University of Technology for 1 h at a constant plasma flow of 4×10<sup>16</sup> D·cm<sup>-2</sup> with 50 eV. Finally, the D retention and desorption behaviors were studied using Thermal Desorption Spectroscopy (TDS), Doppler-broadening Spectroscopy (DBS) of Positron Annihilation, Transmission Electron Microscopy (TEM), and Scanning Electron Microscopy (SEM). SRIM simulations were also conducted to model the defect and D atom distributions in the materials.<bold>Results</bold>Observational findings show that Fe<sup>13+</sup> ion irradiation induces significant vacancy-type defects in both materials, with higher defect concentrations in pure W compared to the alloy. D retention is observed to be higher in pure W, with desorption occurring at approximately 250 °C and 700 °C. In contrast, the 97W-2Ni-1Fe alloy shows reduced D retention, with desorption peaks at 200 °C and 700 °C. The TDS results reveal that pure W retained 2~3 times more D than the alloy. Pre-irradiation with Fe<sup>13+</sup> ions further enhances D retention, especially in pure W. TEM analysis results confirm the formation of D bubbles in the defect regions, especially under high-dose irradiation. Compared to pure tungsten, the deuterium retention of the 97W-2Ni-1Fe alloy decreases by 65.0% and 55.8% under low and high dose pre-irradiation conditions, respectively.<bold>Conclusions</bold>The 97W-2Ni-1Fe alloy demonstrates superior performance in minimizing D retention, with significantly lower D desorption and reduced bubble formation compared to pure W, hence is a more favorable material for applications where minimizing D retention and associated damage is critical, such as in fusion reactors. The results highlight the importance of material composition and defect structure in controlling D behavior under irradiation and plasma conditions, offering valuable insights into the design of next-generation plasma-facing materials.
Authors
- Haiyu Xue
- Daqing Yuan
- te Zhu
- Laima Luo
- Xingzhong CAO
- Sheng Liu
- Peng Zhang
- Pinjing CHENG
- Haibiao WU
Publication Details
- Journal
- Nuclear Techniques
- Published
- 2026-02-01
- DOI
- https://doi.org/10.3724/j.0253-3219.2026.hjs.49.250019
- Primary Topic
- Fusion materials and technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China
- Chinese Academy of Sciences