Design and Verification of Non-Intrusive Current Transformer with PCB Coils in Reverse-Series Connection

Accurate and reliable current measurement is a key prerequisite for ensuring the safe operation of power systems. Conventional through-core and wound current transformers require power outage for installation or modification of line structures, which are plagued by high installation difficulty and cost, and fail to meet the digital development needs of smart grids. To address the demand for non-intrusive installation of current transformers, this paper proposes a non-intrusive current transformer with PCB coils in reverse-series connection. First, a magnetic coupling current calculation model is established to design a reverse-series double-layer coil structure, and a mathematical model of the equivalent circuit for the sensing and measurement system is constructed. The influence of circuit parameters on the output response is analyzed, yielding an optimization method for the system operating state and completing the hardware circuit design. Subsequently, a simulation model of the reverse-series double-layer coil is built to calculate and analyze the amplitude-frequency characteristics, steady-state and transient performance, as well as anti-interference capability of the transformer. The results demonstrate that the designed transformer, combined with an active integrating circuit, achieves an upper cutoff frequency of 13,169 Hz and a lower cutoff frequency approaching 0 Hz, which satisfies the requirements of wide-frequency measurement while ensuring high sensitivity and anti-interference capability. Finally, a current-sensing experiment platform is built for comparative verification with conventional invasive current transformers. Experimental results show that after correction with a proportional coefficient of 1.317, the fitting squared error is only 0.0038. The linearity remains excellent under different conditions with a wide dynamic measurement range, and the phase error is less than 15°. Within the range of 2–120% of the rated current, the ratio error is less than 0.9%, indicating high measurement accuracy. This study provides a new high-precision and convenient method for current measurement in smart grids.

Authors

Institutions

Publication Details

Journal
Designs
Published
2026-02-13
DOI
https://doi.org/10.3390/designs10010020
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Verification of Non-Intrusive Current Transformer with PCB Coils in Reverse-Series Connection

Juheng Wang, JinGang Wang, Xunan Ding, Xiao Chen et al.
Designs
Magnetic Field Sensors Techniques
article

Design and Verification of Non-Intrusive Current Transformer with PCB Coils in Reverse-Series Connection

Juheng Wang, JinGang Wang, Xunan Ding, Xiao Chen, Chenchen Han
article en

Abstract

Accurate and reliable current measurement is a key prerequisite for ensuring the safe operation of power systems. Conventional through-core and wound current transformers require power outage for installation or modification of line structures, which are plagued by high installation difficulty and cost, and fail to meet the digital development needs of smart grids. To address the demand for non-intrusive installation of current transformers, this paper proposes a non-intrusive current transformer with PCB coils in reverse-series connection. First, a magnetic coupling current calculation model is established to design a reverse-series double-layer coil structure, and a mathematical model of the equivalent circuit for the sensing and measurement system is constructed. The influence of circuit parameters on the output response is analyzed, yielding an optimization method for the system operating state and completing the hardware circuit design. Subsequently, a simulation model of the reverse-series double-layer coil is built to calculate and analyze the amplitude-frequency characteristics, steady-state and transient performance, as well as anti-interference capability of the transformer. The results demonstrate that the designed transformer, combined with an active integrating circuit, achieves an upper cutoff frequency of 13,169 Hz and a lower cutoff frequency approaching 0 Hz, which satisfies the requirements of wide-frequency measurement while ensuring high sensitivity and anti-interference capability. Finally, a current-sensing experiment platform is built for comparative verification with conventional invasive current transformers. Experimental results show that after correction with a proportional coefficient of 1.317, the fitting squared error is only 0.0038. The linearity remains excellent under different conditions with a wide dynamic measurement range, and the phase error is less than 15°. Within the range of 2–120% of the rated current, the ratio error is less than 0.9%, indicating high measurement accuracy. This study provides a new high-precision and convenient method for current measurement in smart grids.

DesignsVol. 10(1)
Chongqing University (CN), State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 57%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.