Comparison of point‑of‑care HbA1c devices with laboratory HPLC methods: A systematic review and meta‑analysis

Hemoglobin A1c (HbA1c), also known as glycated hemoglobin, is a cornerstone biomarker for diagnosing and monitoring diabetes. While high-performance liquid chromatography (HPLC) is the reference standard, point-of-care (POC) devices are increasingly used due to convenience and rapid results. However, concerns remain about their analytical accuracy. This systematic review and meta-analysis evaluated the agreement between POC HbA1c devices and laboratory HPLC-based methods. A total of 11 studies involving 1,593 participants and 3,285 paired measurements were included. The pooled mean difference between POC and HPLC was 0.01% [95% confidence interval (CI), -0.08 to 0.11%; 95% prediction interval (PI), -0.443 to 0.471%; P=0.779], well within the clinically acceptable margin of ±0.5%. However, substantial heterogeneity was observed and extensive subgroup analyses across device model, analytical principle, and study characteristics did not fully explain this variability. Notably, some platforms, such as lateral flow immunoassays, exhibited larger biases approaching thresholds relevant to clinical decision-making. Although most POC devices demonstrated acceptable agreement, results highlight the importance of careful validation and interpretation. Future research should prioritize standardized protocols, comparative studies across platforms, and assessment in real-world decentralized settings to enhance confidence in POC HbA1c measurement.

Authors

Institutions

Publication Details

Journal
Biomedical Reports
Published
2026-02-13
DOI
https://doi.org/10.3892/br.2026.2120
Primary Topic
Medication Adherence and Compliance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of point‑of‑care HbA1c devices with laboratory HPLC methods: A systematic review and meta‑analysis

Zhongshuang Hu, Mingze Gu, Yuqing Ren, Yongzhong Wei
Biomedical Reports
Medication Adherence and Compliance
article

Comparison of point‑of‑care HbA1c devices with laboratory HPLC methods: A systematic review and meta‑analysis

Zhongshuang Hu, Mingze Gu, Yuqing Ren, Yongzhong Wei
article en

Abstract

Hemoglobin A1c (HbA1c), also known as glycated hemoglobin, is a cornerstone biomarker for diagnosing and monitoring diabetes. While high-performance liquid chromatography (HPLC) is the reference standard, point-of-care (POC) devices are increasingly used due to convenience and rapid results. However, concerns remain about their analytical accuracy. This systematic review and meta-analysis evaluated the agreement between POC HbA1c devices and laboratory HPLC-based methods. A total of 11 studies involving 1,593 participants and 3,285 paired measurements were included. The pooled mean difference between POC and HPLC was 0.01% [95% confidence interval (CI), -0.08 to 0.11%; 95% prediction interval (PI), -0.443 to 0.471%; P=0.779], well within the clinically acceptable margin of ±0.5%. However, substantial heterogeneity was observed and extensive subgroup analyses across device model, analytical principle, and study characteristics did not fully explain this variability. Notably, some platforms, such as lateral flow immunoassays, exhibited larger biases approaching thresholds relevant to clinical decision-making. Although most POC devices demonstrated acceptable agreement, results highlight the importance of careful validation and interpretation. Future research should prioritize standardized protocols, comparative studies across platforms, and assessment in real-world decentralized settings to enhance confidence in POC HbA1c measurement.

Biomedical ReportsVol. 24(4)
Shanghai Institute of Quality Inspection and Technical Research (CN)
Openalex Percentile: Top 59%
Medication Adherence and Compliance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.