Exergy Analysis Based on AI Correlations for Seawater Properties: Case Study of Industrial MED-TVC Plant in Kuwait

Desalination is an increasingly important element in the sustainable supply of potable water. To accurately predict costs, the efficiency of such systems requires accurate knowledge of seawater’s thermodynamic properties. Four models have been proposed for determining the thermophysical properties of salt water, pure water, an ideal mixture, and an aqueous sodium chloride solution, and empirical correlations, as would be expected, provide the precision necessary for accurate exergy calculations. This research began with a study of the most recent and accurate empirical investigations of the thermodynamic properties of seawater. It then employed AI techniques to develop a simpler, more accurate model for density, Gibbs free energy, specific enthalpy, and specific entropy for pressures extending up to 12 MPa, salinities from 0 to 80 g/kg, and the temperature range of 10 °C to 120 °C. The AI-based correlations achieved absolute errors of 1.5 kg/m3 for density, 0.185 kJ/kg for specific enthalpy, 0.005 kJ/kg·K for specific entropy, and 0.214 kJ/kg for Gibbs free energy. These values demonstrated at least equivalent, and even superior, accuracy to the existing state-of-the-art formulations, with the advantage of significantly reduced computational complexity, enhanced computational efficiency, and a more user-friendly implementation. Validation against experimental data demonstrated the exceptional accuracy of the predicted values for all the stated thermodynamic properties. In addition, an exergy-based assessment was conducted of the performance of a recently commissioned desalination plant in Kuwait. This was a large-scale multi-effect distillation plant with thermal vapour compression (MED-TVC), showing a second-law efficiency of 8.9%, with the primary source of exergy destruction identified as the evaporator units. Comparative assessment with a more conventional approach showed differences of less than 0.4% in total exergy destruction and less than 5% in exergetic efficiency. This is taken as a validation of the accuracy, reliability, and practical usefulness of the proposed AI framework for the performance evaluation of desalination systems.

Authors

Institutions

Publication Details

Journal
Water
Published
2026-02-13
DOI
https://doi.org/10.3390/w18040482
Primary Topic
Membrane Separation Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exergy Analysis Based on AI Correlations for Seawater Properties: Case Study of Industrial MED-TVC Plant in Kuwait

Abdulrahman Alenezi, Abdulrahman Almutairi, Hamad M. Alhajeri, Hani Abulkhair
Water
Membrane Separation Technologies
article

Exergy Analysis Based on AI Correlations for Seawater Properties: Case Study of Industrial MED-TVC Plant in Kuwait

Abdulrahman Alenezi, Abdulrahman Almutairi, Hamad M. Alhajeri, Hani Abulkhair
article en

Abstract

Desalination is an increasingly important element in the sustainable supply of potable water. To accurately predict costs, the efficiency of such systems requires accurate knowledge of seawater’s thermodynamic properties. Four models have been proposed for determining the thermophysical properties of salt water, pure water, an ideal mixture, and an aqueous sodium chloride solution, and empirical correlations, as would be expected, provide the precision necessary for accurate exergy calculations. This research began with a study of the most recent and accurate empirical investigations of the thermodynamic properties of seawater. It then employed AI techniques to develop a simpler, more accurate model for density, Gibbs free energy, specific enthalpy, and specific entropy for pressures extending up to 12 MPa, salinities from 0 to 80 g/kg, and the temperature range of 10 °C to 120 °C. The AI-based correlations achieved absolute errors of 1.5 kg/m3 for density, 0.185 kJ/kg for specific enthalpy, 0.005 kJ/kg·K for specific entropy, and 0.214 kJ/kg for Gibbs free energy. These values demonstrated at least equivalent, and even superior, accuracy to the existing state-of-the-art formulations, with the advantage of significantly reduced computational complexity, enhanced computational efficiency, and a more user-friendly implementation. Validation against experimental data demonstrated the exceptional accuracy of the predicted values for all the stated thermodynamic properties. In addition, an exergy-based assessment was conducted of the performance of a recently commissioned desalination plant in Kuwait. This was a large-scale multi-effect distillation plant with thermal vapour compression (MED-TVC), showing a second-law efficiency of 8.9%, with the primary source of exergy destruction identified as the evaporator units. Comparative assessment with a more conventional approach showed differences of less than 0.4% in total exergy destruction and less than 5% in exergetic efficiency. This is taken as a validation of the accuracy, reliability, and practical usefulness of the proposed AI framework for the performance evaluation of desalination systems.

WaterVol. 18(4)
Public Authority for Applied Education and Training (KW), King Abdulaziz University (SA)
King Abdulaziz University
Openalex Percentile: Top 59%
Membrane Separation Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.