Concept of a Vertical Observation System for CXRS Diagnostics at the TRT Tokamak

The TRT (Tokamak with Reactor Technologies) should be an important step in the implementation of the Russian national program of controlled thermonuclear fusion. The main task of the TRT facility is to obtain a long-term plasma pulse, which is possible only if superconducting coils are used. To control the parameters of thermonuclear plasma, it is necessary to develop and create an entire complex of diagnostic systems. One of the designed diagnostic systems for the TRT is the diagnostics of “active spectroscopy” (AS), referred to in the English literature by the abbreviation CXRS (Charge eXchange Recombination Spectroscopy). In an earlier publication [1] the possibility of creating this diagnostics was considered both on a heating and on a diagnostic beam of atoms, and it was shown that the diagnostics would work only using a diagnostic beam of atoms. At the same time, only the implementation of the observation system in the horizontal plane from the equatorial port of the TRT facility was considered. This paper presents the concept of a vertical observation system for the diagnostics of CXRS on the TRT facility. A vertical observation system is necessary to measure the poloidal rotational velocity at the edge of the plasma. The paper presents the results of modeling of light spectral profiles emitted by plasma and estimates of the levels of active and background signals, as well as the signal-to-noise ratio. A measurement scheme is proposed for simultaneous registration of emission over a minor radius from r = 0.8a to r = a. The optical system for collecting light from plasma is described, and a description of the proposed measuring equipment is given. The plasma parameters measurement accuracy and the achievable spatial resolution are estimated.

Authors

Publication Details

Journal
Physics of Atomic Nuclei
Published
2025-12-01
DOI
https://doi.org/10.1134/s1063778825140108
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concept of a Vertical Observation System for CXRS Diagnostics at the TRT Tokamak

G. S. Pavlova, V. V. Serov, N. V. Kuzmin, S. N. Tugarinov
Physics of Atomic Nuclei
Magnetic confinement fusion research
article

Concept of a Vertical Observation System for CXRS Diagnostics at the TRT Tokamak

G. S. Pavlova, V. V. Serov, N. V. Kuzmin, S. N. Tugarinov
article en

Abstract

The TRT (Tokamak with Reactor Technologies) should be an important step in the implementation of the Russian national program of controlled thermonuclear fusion. The main task of the TRT facility is to obtain a long-term plasma pulse, which is possible only if superconducting coils are used. To control the parameters of thermonuclear plasma, it is necessary to develop and create an entire complex of diagnostic systems. One of the designed diagnostic systems for the TRT is the diagnostics of “active spectroscopy” (AS), referred to in the English literature by the abbreviation CXRS (Charge eXchange Recombination Spectroscopy). In an earlier publication [1] the possibility of creating this diagnostics was considered both on a heating and on a diagnostic beam of atoms, and it was shown that the diagnostics would work only using a diagnostic beam of atoms. At the same time, only the implementation of the observation system in the horizontal plane from the equatorial port of the TRT facility was considered. This paper presents the concept of a vertical observation system for the diagnostics of CXRS on the TRT facility. A vertical observation system is necessary to measure the poloidal rotational velocity at the edge of the plasma. The paper presents the results of modeling of light spectral profiles emitted by plasma and estimates of the levels of active and background signals, as well as the signal-to-noise ratio. A measurement scheme is proposed for simultaneous registration of emission over a minor radius from r = 0.8a to r = a. The optical system for collecting light from plasma is described, and a description of the proposed measuring equipment is given. The plasma parameters measurement accuracy and the achievable spatial resolution are estimated.

Physics of Atomic NucleiVol. 88(S2)
Openalex Percentile: Top 18%
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.