Super-Resolution Reconstruction and Detector Geometric Error Correction for Parallel-Beam Low-Resolution Multi-Detector SPECT: A Proof of Concept

<b>Objectives:</b> Due to collimator limitations, Single-Photon Emission Computed Tomography (SPECT) suffers from relatively low spatial resolution, which hampers the detection of small lesions. This study proposes a super-resolution (SR) reconstruction algorithm for a parallel-beam, low-resolution (LR) multi-detector SPECT system and employs a neural network to estimate and correct for geometric errors in the LR detectors. <b>Methods:</b> A parallel-beam LR multi-detector SPECT system is presented, in which the detectors perform relative sub-pixel shifts. At each sampling angle, an SR reconstruction algorithm synthesizes high-resolution (HR) SPECT images from LR projections acquired by four offset LR detectors. To correct for geometric errors among these detectors, a randomly distributed gamma point source was designed to generate training data. A neural network was then employed to estimate the geometric errors, thereby refining the SR reconstruction. <b>Results:</b> Numerical simulation demonstrated that the proposed neural network could accurately identify the displacement-based geometric errors of the LR detectors. Utilizing these estimated parameters to correct the SR reconstruction process yielded results comparable to those obtained from direct reconstruction of HR projections, achieving a two-fold resolution improvement. <b>Conclusions:</b> Preliminary proof-of-principle for SR reconstruction in a parallel-beam LR multi-detector SPECT system was established. Further validation of the hardware performance is warranted.

Authors

Institutions

Publication Details

Journal
Tomography
Published
2026-02-12
DOI
https://doi.org/10.3390/tomography12020023
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Super-Resolution Reconstruction and Detector Geometric Error Correction for Parallel-Beam Low-Resolution Multi-Detector SPECT: A Proof of Concept

Zhibiao Cheng, Junhai Wen, Ping Chen, Jun Zhang
Tomography
Medical Imaging Techniques and Applications
article

Super-Resolution Reconstruction and Detector Geometric Error Correction for Parallel-Beam Low-Resolution Multi-Detector SPECT: A Proof of Concept

Zhibiao Cheng, Junhai Wen, Ping Chen, Jun Zhang
article en

Abstract

<b>Objectives:</b> Due to collimator limitations, Single-Photon Emission Computed Tomography (SPECT) suffers from relatively low spatial resolution, which hampers the detection of small lesions. This study proposes a super-resolution (SR) reconstruction algorithm for a parallel-beam, low-resolution (LR) multi-detector SPECT system and employs a neural network to estimate and correct for geometric errors in the LR detectors. <b>Methods:</b> A parallel-beam LR multi-detector SPECT system is presented, in which the detectors perform relative sub-pixel shifts. At each sampling angle, an SR reconstruction algorithm synthesizes high-resolution (HR) SPECT images from LR projections acquired by four offset LR detectors. To correct for geometric errors among these detectors, a randomly distributed gamma point source was designed to generate training data. A neural network was then employed to estimate the geometric errors, thereby refining the SR reconstruction. <b>Results:</b> Numerical simulation demonstrated that the proposed neural network could accurately identify the displacement-based geometric errors of the LR detectors. Utilizing these estimated parameters to correct the SR reconstruction process yielded results comparable to those obtained from direct reconstruction of HR projections, achieving a two-fold resolution improvement. <b>Conclusions:</b> Preliminary proof-of-principle for SR reconstruction in a parallel-beam LR multi-detector SPECT system was established. Further validation of the hardware performance is warranted.

TomographyVol. 12(2)
Beijing Institute of Technology (CN), North University of China (CN), Taiyuan University of Science and Technology (CN), Taiyuan University of Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 57%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.