Two-photon voltage imaging with rhodopsin-based sensors

Advances in optical techniques and two-photon (2P) sensitive genetic voltage indicators (GEVIs) enabled in-depth voltage imaging at single-spike and single-cell resolution. These results were achieved using ASAP-type sensors, while rhodopsin-based GEVIs were mainly used with one-photon (1P) illumination. Here, we demonstrate compatibility of rhodopsin-based GEVIs with 2P illumination. We rationally engineer a fully genetically encoded, rhodopsin-based GEVI, just another voltage indicating sensor (Jarvis), and demonstrate its utility under 1P and 2P illumination. We further show 2P usability of the fluorescence resonance energy transfer (FRET)-opsin GEVIs pAce and Voltron2. Comparing 2P scanless with fast 2P scanning illumination revealed that responses are resolved with both approaches, but FRET-opsin GEVIs show improved signal-to-noise ratio (SNR) with low irradiance, inherent to scanless illumination. Utilizing Jarvis and pAce, we establish high-SNR action potential detection at kilohertz imaging rates in mouse hippocampal slices, zebrafish larvae, and the cortex of awake mice, demonstrating high-contrast action potential detection under 2P illumination with rhodopsin-based GEVIs in vitro and in vivo.

Authors

Institutions

Publication Details

Journal
Neuron
Published
2026-02-01
DOI
https://doi.org/10.1016/j.neuron.2025.12.014
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-photon voltage imaging with rhodopsin-based sensors

Ruth R. Sims, Aysha S. Mohamed Lafirdeen, Eirini Papagiakoumou, Giulia Faini et al.
Neuron
Advanced Fluorescence Microscopy Techniques
article

Two-photon voltage imaging with rhodopsin-based sensors

Ruth R. Sims, Aysha S. Mohamed Lafirdeen, Eirini Papagiakoumou, Giulia Faini, Chung Chan, Elena Putti, Dimitrii Tanese, Christiane Grimm, Imane Bendifallah, Filippo Del Bene, Valentina Emiliani
article en

Abstract

Advances in optical techniques and two-photon (2P) sensitive genetic voltage indicators (GEVIs) enabled in-depth voltage imaging at single-spike and single-cell resolution. These results were achieved using ASAP-type sensors, while rhodopsin-based GEVIs were mainly used with one-photon (1P) illumination. Here, we demonstrate compatibility of rhodopsin-based GEVIs with 2P illumination. We rationally engineer a fully genetically encoded, rhodopsin-based GEVI, just another voltage indicating sensor (Jarvis), and demonstrate its utility under 1P and 2P illumination. We further show 2P usability of the fluorescence resonance energy transfer (FRET)-opsin GEVIs pAce and Voltron2. Comparing 2P scanless with fast 2P scanning illumination revealed that responses are resolved with both approaches, but FRET-opsin GEVIs show improved signal-to-noise ratio (SNR) with low irradiance, inherent to scanless illumination. Utilizing Jarvis and pAce, we establish high-SNR action potential detection at kilohertz imaging rates in mouse hippocampal slices, zebrafish larvae, and the cortex of awake mice, demonstrating high-contrast action potential detection under 2P illumination with rhodopsin-based GEVIs in vitro and in vivo.

Neuron
Centre National de la Recherche Scientifique (FR), Institut de la Vision (FR), Inserm (FR), Sorbonne Université (FR)
Affordable and clean energy
Openalex Percentile: Top 63%
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.