A Chromatographic Approach for Simultaneous Quantification of Multiple Anticoagulants in Human Plasma Samples

Anticoagulants are essential drugs for preventing and treating thromboembolic conditions by inhibiting blood clot formation. Warfarin, a vitamin K antagonist, is among the most prescribed agents but presents limitations, including a narrow therapeutic window and a high risk of adverse events, requiring strict monitoring to ensure both safety and therapeutic efficacy. In contrast, direct oral anticoagulants such as dabigatran, rivaroxaban, and apixaban offer improved safety profiles and generally do not require routine monitoring. Nevertheless, monitoring is required in special clinical situations, including emergencies, renal dysfunction, or for high-risk patients. In this context, the present study aimed to develop an HPLC method with UV/Vis detection for the simultaneous quantification of four anticoagulant agents (warfarin, dabigatran, rivaroxaban, and apixaban) in human plasma. Efficient separation of the four target analytes involved the evaluation of several parameters, including column type (Kinetex core-shell C18, Chromolith RP-18e, and Chromolith Phenyl), elution conditions, and injection volume (10-50 µL). The best separation was achieved within 12 min using a monolithic phenyl column and gradient elution, at a flow rate of 2 mL/min. The method was validated and has shown to be selective, linear in the range of 0.50-5.0 µg/mL for dabigatran and warfarin and 0.25-5.0 µg/mL for rivaroxaban and apixaban, accurate (85.7%-115.0%), and precise (CV ≤ 9.4%) for both intra- and inter-day assays. LOD and LOQ in plasma were ≤ 0.2 and ≤ 0.5 µg/mL, respectively. Stability testing demonstrated that all analytes remained stable at room temperature for 24 h, with only dabigatran showing reduced stability after three freeze-thaw cycles. The proposed method enabled rapid and simultaneous quantification of four clinically relevant anticoagulants in plasma samples.

Authors

Institutions

Publication Details

Journal
Journal of Separation Science
Published
2026-02-01
DOI
https://doi.org/10.1002/jssc.70370
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Chromatographic Approach for Simultaneous Quantification of Multiple Anticoagulants in Human Plasma Samples

Marcela Segundo, Federica Guidetti, Luisa Barreiros, Sara R. Fernandes
Journal of Separation Science
Atrial Fibrillation Management and Outcomes
article

A Chromatographic Approach for Simultaneous Quantification of Multiple Anticoagulants in Human Plasma Samples

Marcela Segundo, Federica Guidetti, Luisa Barreiros, Sara R. Fernandes
article en

Abstract

Anticoagulants are essential drugs for preventing and treating thromboembolic conditions by inhibiting blood clot formation. Warfarin, a vitamin K antagonist, is among the most prescribed agents but presents limitations, including a narrow therapeutic window and a high risk of adverse events, requiring strict monitoring to ensure both safety and therapeutic efficacy. In contrast, direct oral anticoagulants such as dabigatran, rivaroxaban, and apixaban offer improved safety profiles and generally do not require routine monitoring. Nevertheless, monitoring is required in special clinical situations, including emergencies, renal dysfunction, or for high-risk patients. In this context, the present study aimed to develop an HPLC method with UV/Vis detection for the simultaneous quantification of four anticoagulant agents (warfarin, dabigatran, rivaroxaban, and apixaban) in human plasma. Efficient separation of the four target analytes involved the evaluation of several parameters, including column type (Kinetex core-shell C18, Chromolith RP-18e, and Chromolith Phenyl), elution conditions, and injection volume (10-50 µL). The best separation was achieved within 12 min using a monolithic phenyl column and gradient elution, at a flow rate of 2 mL/min. The method was validated and has shown to be selective, linear in the range of 0.50-5.0 µg/mL for dabigatran and warfarin and 0.25-5.0 µg/mL for rivaroxaban and apixaban, accurate (85.7%-115.0%), and precise (CV ≤ 9.4%) for both intra- and inter-day assays. LOD and LOQ in plasma were ≤ 0.2 and ≤ 0.5 µg/mL, respectively. Stability testing demonstrated that all analytes remained stable at room temperature for 24 h, with only dabigatran showing reduced stability after three freeze-thaw cycles. The proposed method enabled rapid and simultaneous quantification of four clinically relevant anticoagulants in plasma samples.

Journal of Separation ScienceVol. 49(2)
Universidade do Porto (PT), Rede de Química e Tecnologia (PT), Polytechnic Institute of Porto (PT)
Ministério da Educação, Fundação para a Ciência e a Tecnologia, European Social Fund
Good health and well-being
Openalex Percentile: Top 60%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.