Design of Detection Training Equipment for Penetrating Radiation Field from Nuclear Fuel in a Tunnel Environment

To address the problems existing in nuclear reactor accident emergency training, a design scheme and system prototype of radiation detection training equipment for penetrating radiation fields in enclosed spaces, based on inertial sensors and wireless Bluetooth communication is proposed. First, the penetrating radiation field is modeled. On this basis, a calculation model of the neutron/<i>γ</i> dose equivalent rate is established. This model is based on the motion path of simulated radiation detection equipment. Second, the MPU6050 inertial sensor is designed and developed. It monitors the three-axis acceleration and three-axis angular acceleration values in real time. This enables the indoor positioning function of the simulated detection training equipment. The Digital Motion Processor (DMP) filtering algorithm is used to process the measured data. This improves the detection accuracy. Finally, a Bluetooth communication module is designed and developed. It transmits the detected position data to the main control computer in real time. The main control computer performs calculation and analysis to obtain the radiation intensity value. This value is sent to the Arduino controller. The Arduino controller controls the display of the value on the liquid crystal screen. Experimental verification is carried out. Experimental verification indicates that the maximum error of the system's three-dimensional spatial positioning is 0.08 m, the mean relative error of the radiation dose rate simulation is 4.81%, and the maximum relative error is 7.8%. The system relatively accurately achieves radiation dose simulation and radiation source localization according to different working modes, providing a high cost-effectiveness training method for radiation detection training with high safety and good economy.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-12
DOI
https://doi.org/10.3390/s26041194
Primary Topic
Radioactive contamination and transfer
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Detection Training Equipment for Penetrating Radiation Field from Nuclear Fuel in a Tunnel Environment

Fei Wu, Hui Li, Xin Xie, B Ghelich Li et al.
Sensors
Radioactive contamination and transfer
article

Design of Detection Training Equipment for Penetrating Radiation Field from Nuclear Fuel in a Tunnel Environment

Fei Wu, Hui Li, Xin Xie, B Ghelich Li, Gui Chao Huang, Ming Guo
article en

Abstract

To address the problems existing in nuclear reactor accident emergency training, a design scheme and system prototype of radiation detection training equipment for penetrating radiation fields in enclosed spaces, based on inertial sensors and wireless Bluetooth communication is proposed. First, the penetrating radiation field is modeled. On this basis, a calculation model of the neutron/<i>γ</i> dose equivalent rate is established. This model is based on the motion path of simulated radiation detection equipment. Second, the MPU6050 inertial sensor is designed and developed. It monitors the three-axis acceleration and three-axis angular acceleration values in real time. This enables the indoor positioning function of the simulated detection training equipment. The Digital Motion Processor (DMP) filtering algorithm is used to process the measured data. This improves the detection accuracy. Finally, a Bluetooth communication module is designed and developed. It transmits the detected position data to the main control computer in real time. The main control computer performs calculation and analysis to obtain the radiation intensity value. This value is sent to the Arduino controller. The Arduino controller controls the display of the value on the liquid crystal screen. Experimental verification is carried out. Experimental verification indicates that the maximum error of the system's three-dimensional spatial positioning is 0.08 m, the mean relative error of the radiation dose rate simulation is 4.81%, and the maximum relative error is 7.8%. The system relatively accurately achieves radiation dose simulation and radiation source localization according to different working modes, providing a high cost-effectiveness training method for radiation detection training with high safety and good economy.

SensorsVol. 26(4)
Naval University of Engineering (CN)
Openalex Percentile: Top 69%
Radioactive contamination and transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.