Analysis of Induced Voltage Due to AC Electromagnetic Effect in Metal Supporting Structures of 22.9kV Three-Phase Power Cables

In power systems, cable arrangements strongly influence electrical, thermal, and spatial performance. Underground cables are typically installed in trefoil or flat configurations, with cleats placed at intervals to ensure stability under fault-induced electromagnetic forces. However, these arrangements may produce induced voltages and induced currents in the sheath, reducing reliability. Floating conductors, such as ungrounded cleats, can further enhance electromagnetic coupling and generate additional induced voltages. This study uses Finite Element Method (FEM) simulations on a cross-bonded trefoil cable model to analyze these effects. Results show that induced voltages arise from the combined action of electric and magnetic fields and are strongly affected by cleat conductivity. The findings indicate that induced voltages on floating conductors may accelerate insulation degradation and increase safety hazards, highlighting the need for proper cleat design and bonding practices.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2026-02-12
DOI
https://doi.org/10.5370/kiee.2026.75.2.356
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Induced Voltage Due to AC Electromagnetic Effect in Metal Supporting Structures of 22.9kV Three-Phase Power Cables

Hyo-Jun Shin, Hyeong-Jun Kim, Minwoo Jeong, Yong-Hee Kim et al.
The Transactions of The Korean Institute of Electrical Engineers
Thermal Analysis in Power Transmission
article

Analysis of Induced Voltage Due to AC Electromagnetic Effect in Metal Supporting Structures of 22.9kV Three-Phase Power Cables

Hyo-Jun Shin, Hyeong-Jun Kim, Minwoo Jeong, Yong-Hee Kim, Chae-Won Kim, Se-Hee Lee
article en

Abstract

In power systems, cable arrangements strongly influence electrical, thermal, and spatial performance. Underground cables are typically installed in trefoil or flat configurations, with cleats placed at intervals to ensure stability under fault-induced electromagnetic forces. However, these arrangements may produce induced voltages and induced currents in the sheath, reducing reliability. Floating conductors, such as ungrounded cleats, can further enhance electromagnetic coupling and generate additional induced voltages. This study uses Finite Element Method (FEM) simulations on a cross-bonded trefoil cable model to analyze these effects. Results show that induced voltages arise from the combined action of electric and magnetic fields and are strongly affected by cleat conductivity. The findings indicate that induced voltages on floating conductors may accelerate insulation degradation and increase safety hazards, highlighting the need for proper cleat design and bonding practices.

The Transactions of The Korean Institute of Electrical EngineersVol. 75(2)
Affordable and clean energy
Openalex Percentile: Top 58%
Thermal Analysis in Power Transmission
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Induced Voltage Due to AC Electromagnetic Effect in Metal Supporting Structures of 22.9kV Three-Phase Power Cables — Hyo-Jun Shin, Hyeong-Jun Kim, et al. · The Transactions of The Korean Institute of Electrical Engineers (2026) | TGRS Research Map | TGRS