Minute-by-minute systemic hemodynamic responses to packed red blood cell transfusion in extremely low gestational age neonates: a prospective cohort study

This study is the first to apply Electrical Velocimetry (EV) for continuous, high-resolution monitoring of systemic hemodynamic (SH) parameters before, during, and after packed red blood cell transfusion (PRBCT) in extremely low-gestational-age neonates (ELGANs). The findings demonstrate measurable minute-by-minute fluctuations in cardiac contractility, stroke volume, cardiac output and vascular resistance temporally associated with transfusion. These fluctuations occurred even in infants who were hemodynamically stable at baseline, suggesting that EV may detect transfusion-related physiological variability not captured by routine monitoring, without implying a direct causal effect. Advanced monitoring technologies, such as EV, may enable more accurate and individualized neonatal care. To optimize outcomes for this vulnerable population and refine transfusion guidelines, further research including larger prospective studies and randomized controlled trials are needed.

Authors

Institutions

Publication Details

Journal
Pediatric Research
Published
2026-02-12
DOI
https://doi.org/10.1038/s41390-026-04805-y
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Minute-by-minute systemic hemodynamic responses to packed red blood cell transfusion in extremely low gestational age neonates: a prospective cohort study

Samir Gupta, Phani Kiran Yajamanyam, Sanoj Karayil Mohammad Ali, Venkat Reddy Kallem et al.
Pediatric Research
Neonatal Respiratory Health Research
article

Minute-by-minute systemic hemodynamic responses to packed red blood cell transfusion in extremely low gestational age neonates: a prospective cohort study

Samir Gupta, Phani Kiran Yajamanyam, Sanoj Karayil Mohammad Ali, Venkat Reddy Kallem, Aravanan Anbu Chakkarapani, Kiran More, Treesa Jilson, Aisha Kamil Mohamed Khalifa, Zainab Awada, Asma Jamil, Naharmal Soni
article en

Abstract

This study is the first to apply Electrical Velocimetry (EV) for continuous, high-resolution monitoring of systemic hemodynamic (SH) parameters before, during, and after packed red blood cell transfusion (PRBCT) in extremely low-gestational-age neonates (ELGANs). The findings demonstrate measurable minute-by-minute fluctuations in cardiac contractility, stroke volume, cardiac output and vascular resistance temporally associated with transfusion. These fluctuations occurred even in infants who were hemodynamically stable at baseline, suggesting that EV may detect transfusion-related physiological variability not captured by routine monitoring, without implying a direct causal effect. Advanced monitoring technologies, such as EV, may enable more accurate and individualized neonatal care. To optimize outcomes for this vulnerable population and refine transfusion guidelines, further research including larger prospective studies and randomized controlled trials are needed.

Pediatric Research
Qatar Airways (Qatar) (QA), Durham University (GB), Paras Hospitals (IN), Sidra Medical and Research Center (QA), Weill Cornell Medical College in Qatar (QA), SRCC Children’s Hospital (IN)
Qatar National Library
Good health and well-being
Openalex Percentile: Top 60%
Neonatal Respiratory Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.