DC fault detection and classification using time-derivative of butterworth highpass filtered currents without threshold

• Eliminates threshold setting by selecting sensitivity above the transient. • Fault classification using polarity asymmetry driven by cutoff frequency. • Concurrent fault detection and classification in a unified step. • Validation demonstrated by both simulation and hardware prototype. DC transmission is efficient and renewable-friendly, but high-frequency capacitive discharge during faults necessitates fast and reliable fault detection and classification. Therefore, this paper presents a method based on the time derivative of a Butterworth Highpass Filter (HPF), validated through simulation and a hardware prototype. The HPF isolates the high-frequency components of measured pole currents for fault detection, while an optimised cutoff frequency enhances fault classification. The time derivative further accelerates detection by tracking change rates rather than peak magnitude. The Butterworth response is monotonic, stable, and comparable. Thus, both poles’ derivatives are normalised with identical sensitivity above the charging transient, avoiding predefined thresholds. Comparing these normalised derivatives enables simultaneous fault detection and classification.

Authors

Institutions

Publication Details

Journal
Electric Power Systems Research
Published
2026-02-12
DOI
https://doi.org/10.1016/j.epsr.2026.112830
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DC fault detection and classification using time-derivative of butterworth highpass filtered currents without threshold

Abhisek Ukil, Assoc. Prof. Nirmal-Kumar C Nair, Saad Ahmed Khan
Electric Power Systems Research
Electrical Fault Detection and Protection
article

DC fault detection and classification using time-derivative of butterworth highpass filtered currents without threshold

Abhisek Ukil, Assoc. Prof. Nirmal-Kumar C Nair, Saad Ahmed Khan
article en

Abstract

• Eliminates threshold setting by selecting sensitivity above the transient. • Fault classification using polarity asymmetry driven by cutoff frequency. • Concurrent fault detection and classification in a unified step. • Validation demonstrated by both simulation and hardware prototype. DC transmission is efficient and renewable-friendly, but high-frequency capacitive discharge during faults necessitates fast and reliable fault detection and classification. Therefore, this paper presents a method based on the time derivative of a Butterworth Highpass Filter (HPF), validated through simulation and a hardware prototype. The HPF isolates the high-frequency components of measured pole currents for fault detection, while an optimised cutoff frequency enhances fault classification. The time derivative further accelerates detection by tracking change rates rather than peak magnitude. The Butterworth response is monotonic, stable, and comparable. Thus, both poles’ derivatives are normalised with identical sensitivity above the charging transient, avoiding predefined thresholds. Comparing these normalised derivatives enables simultaneous fault detection and classification.

Electric Power Systems ResearchVol. 255
University of Auckland (NZ)
Openalex Percentile: Top 57%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.