Marginal Fit Evaluation of Zirconia Copings Based on Conventional and Digital Impressions Using a Tooth Section Microscopic Examination Technique

<b>Background/Objectives:</b> This study compared the marginal fit of CAD/CAM zirconia copings based on digital and conventional impression techniques by using a new method of tooth section examination. <b>Methods:</b> Twenty premolars were prepared for an all-ceramic full crown. Ten conventional impressions using the polyether Impregum and ten digital impressions using the cara TRIOS intraoral scanner were used to fabricate zirconia copings. Slices were prepared by cutting each tooth five times. The marginal fit was microscopically analyzed using seven defined distances at 20 measuring points per tooth. The statistical analyses were carried out by using the Mann-Whitney test and the Kruskal-Wallis test (α = 0.05). <b>Results:</b> The median values for the copings based on the conventional (c) and digital (d) impressions showed significant differences for the internal gap (c: 56 μm (IQR = 22); d: 30 μm (IQR = 13); <i>p</i> < 0.001), horizontal marginal discrepancy (c: 64 μm (IQR = 59); d: 84 μm (IQR = 41); <i>p</i> < 0.001), absolute marginal discrepancy (c: 81 μm (IQR = 40); d: 98 μm (IQR = 50); <i>p</i> < 0.001) and the overextension (c: 63 μm (IQR = 48); d: 89 μm (IQR = 50); <i>p</i> < 0.001). All copings based on digital impressions were overextended. Underextensions only occurred with the conventional impression method with a median value of 40 μm (IQR = 64). For the marginal gap (c: 29 μm (IQR = 27); d: 31 μm (IQR = 22); <i>p</i> = 0.477) and the vertical marginal discrepancy (c: 34 μm (IQR = 32); d: 35 μm (IQR = 40); <i>p</i> = 0.944) no significant differences could be found. <b>Conclusions:</b> Both impression methods are suitable for the fabrication of ceramic copings. The microscopic examination of tooth sections seems to be a suitable in vitro method for the evaluation of the marginal fit of ceramic copings.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2026-02-12
DOI
https://doi.org/10.3390/dj14020106
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Marginal Fit Evaluation of Zirconia Copings Based on Conventional and Digital Impressions Using a Tooth Section Microscopic Examination Technique

Peter Ottl, Mareike Warkentin, Marc Schulze
Dentistry Journal
Dental materials and restorations
article

Marginal Fit Evaluation of Zirconia Copings Based on Conventional and Digital Impressions Using a Tooth Section Microscopic Examination Technique

Peter Ottl, Mareike Warkentin, Marc Schulze
article en

Abstract

<b>Background/Objectives:</b> This study compared the marginal fit of CAD/CAM zirconia copings based on digital and conventional impression techniques by using a new method of tooth section examination. <b>Methods:</b> Twenty premolars were prepared for an all-ceramic full crown. Ten conventional impressions using the polyether Impregum and ten digital impressions using the cara TRIOS intraoral scanner were used to fabricate zirconia copings. Slices were prepared by cutting each tooth five times. The marginal fit was microscopically analyzed using seven defined distances at 20 measuring points per tooth. The statistical analyses were carried out by using the Mann-Whitney test and the Kruskal-Wallis test (α = 0.05). <b>Results:</b> The median values for the copings based on the conventional (c) and digital (d) impressions showed significant differences for the internal gap (c: 56 μm (IQR = 22); d: 30 μm (IQR = 13); <i>p</i> < 0.001), horizontal marginal discrepancy (c: 64 μm (IQR = 59); d: 84 μm (IQR = 41); <i>p</i> < 0.001), absolute marginal discrepancy (c: 81 μm (IQR = 40); d: 98 μm (IQR = 50); <i>p</i> < 0.001) and the overextension (c: 63 μm (IQR = 48); d: 89 μm (IQR = 50); <i>p</i> < 0.001). All copings based on digital impressions were overextended. Underextensions only occurred with the conventional impression method with a median value of 40 μm (IQR = 64). For the marginal gap (c: 29 μm (IQR = 27); d: 31 μm (IQR = 22); <i>p</i> = 0.477) and the vertical marginal discrepancy (c: 34 μm (IQR = 32); d: 35 μm (IQR = 40); <i>p</i> = 0.944) no significant differences could be found. <b>Conclusions:</b> Both impression methods are suitable for the fabrication of ceramic copings. The microscopic examination of tooth sections seems to be a suitable in vitro method for the evaluation of the marginal fit of ceramic copings.

Dentistry JournalVol. 14(2)
Institute for ImplantTechnology and Biomaterials (DE), University of Rostock (DE)
Universität Rostock
Openalex Percentile: Top 57%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.