Construction of multi-component CuO/ZIF-8@CNTs modified electrode for sensitive electrochemical detection of neohesperidin dihydrochalcone in liquor samples

A sensitive electrochemical sensor was proposed for neohesperidin dihydrochalcone (NHDC) detection using copper oxide/ zinc imidazole framework 8@ carbon nanotubes modified glassy carbon electrode (CuO/ZIF-8@CNTs GCE). The multi-component CuO/ZIF-8@CNTs GCE was prepared by two-step drop-casting method and characterized by Field-emission scanning electron microscopy (FE-SEM). The effective combination of CuO and ZIF-8@CNTs enhanced the electron transfer and catalytic activity of the electrode and greatly strengthened the oxidation current of NHDC, which was about 5.6-fold that of the CuO GCE and 2.3-fold that of the ZIF-8@CNTs GCE. Inspired by this, the CuO/ZIF-8@CNTs GCE was used for NHDC detection and some crucial parameters were optimized. The reaction mechanism at CuO/ZIF-8@CNTs GCE was confirmed to involve two-step two-electron process by cyclic voltammetry (CV) measurements. Finally, the sensor achieved NHDC detection ranging from 0.03 to 10 μM using differential pulse voltammetry (DPV) technique, with a detection limit of 16.0 nM. The satisfactory recoveries of 92.9% to 107.8% in liquor samples also demonstrated its practicability in actual samples, matching well with that of high-performance liquid chromatography (HPLC). This work not only designs a simple detection method for NHDC but also opens up a paradigm for leveraging multi-component MOF composite electrode materials for food safety monitoring. • A simple and sensitive electrochemical method was proposed for NHDC detection. • The multi-component CuO/ZIF-8@CNTs GCE showed good selectivity and reproducibility. • The CuO/ZIF-8@CNTs GCE had satisfactory recovery for NHDC detection in liquor samples.

Authors

Institutions

Publication Details

Journal
Journal of Food Composition and Analysis
Published
2026-02-12
DOI
https://doi.org/10.1016/j.jfca.2026.108987
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Construction of multi-component CuO/ZIF-8@CNTs modified electrode for sensitive electrochemical detection of neohesperidin dihydrochalcone in liquor samples

Dongyun Huang, Junhui Xu, Xiaolun Peng, Yue Wang et al.
Journal of Food Composition and Analysis
Electrochemical sensors and biosensors
article

Construction of multi-component CuO/ZIF-8@CNTs modified electrode for sensitive electrochemical detection of neohesperidin dihydrochalcone in liquor samples

Dongyun Huang, Junhui Xu, Xiaolun Peng, Yue Wang, Xingyao Li, Ruijie Xu, Liang Zhang
article en

Abstract

A sensitive electrochemical sensor was proposed for neohesperidin dihydrochalcone (NHDC) detection using copper oxide/ zinc imidazole framework 8@ carbon nanotubes modified glassy carbon electrode (CuO/ZIF-8@CNTs GCE). The multi-component CuO/ZIF-8@CNTs GCE was prepared by two-step drop-casting method and characterized by Field-emission scanning electron microscopy (FE-SEM). The effective combination of CuO and ZIF-8@CNTs enhanced the electron transfer and catalytic activity of the electrode and greatly strengthened the oxidation current of NHDC, which was about 5.6-fold that of the CuO GCE and 2.3-fold that of the ZIF-8@CNTs GCE. Inspired by this, the CuO/ZIF-8@CNTs GCE was used for NHDC detection and some crucial parameters were optimized. The reaction mechanism at CuO/ZIF-8@CNTs GCE was confirmed to involve two-step two-electron process by cyclic voltammetry (CV) measurements. Finally, the sensor achieved NHDC detection ranging from 0.03 to 10 μM using differential pulse voltammetry (DPV) technique, with a detection limit of 16.0 nM. The satisfactory recoveries of 92.9% to 107.8% in liquor samples also demonstrated its practicability in actual samples, matching well with that of high-performance liquid chromatography (HPLC). This work not only designs a simple detection method for NHDC but also opens up a paradigm for leveraging multi-component MOF composite electrode materials for food safety monitoring. • A simple and sensitive electrochemical method was proposed for NHDC detection. • The multi-component CuO/ZIF-8@CNTs GCE showed good selectivity and reproducibility. • The CuO/ZIF-8@CNTs GCE had satisfactory recovery for NHDC detection in liquor samples.

Journal of Food Composition and AnalysisVol. 151
Jianghan University (CN)
Openalex Percentile: Top 57%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.