Research on aerodynamic performances of the vertical-axis wind turbines under different wind gust configurations: comparative numerical modeling

Vertical Axis Wind Turbines (VAWT) offer a viable sustainable alternative, with improved efficiency at moderate to low wind speeds. However, the lower starting of VAWTS, with vibration and stability issues is still significant challenging for large-scale utilization development. The present work investigates the performance of a VAWT under different gust shapes (step and sine-wave) at steady and unsteady wind conditions. Computational Fluid Dynamics (CFD) simulations are performed to analyze the aerodynamic performance of the distinct VAWT prototype under varying wind gusts. The local wind data for Dhahran, Saudi Arabia, is used to identify the representative gust profiles and evaluate the wind turbine performance. Moreover, the effects of time period variation of the gust, gust frequency, and azimuthal angle on the wind turbine performance are also investigated. The study is also extended to compare the performance of the proposed wind gusts against a standard gust model defined by the International Electrotechnical Commission (IEC) to provide a better understanding of its dynamic response in actual wind gust conditions. The results demonstrated that as wind velocity during the gust increases, the effective tip speed ratio reduces, whereas the aerodynamic moment of the turbine increases. This increase is directly proportional to the amplitude of the gust. Unsteady simulations also revealed a coupled behavior between the wind velocity and wind turbine power coefficient. It is found that when the wind velocity during the gust increased by 12%, the turbine power coefficient increased by 12%, and the energy coefficient of the turbine reduced by 22%. A further analysis of three frequencies (0.36, 0.46, and 0.56 Hz) at constant amplitude showed that higher-frequency gusts cause faster wind changes, affecting dynamic stall and reducing power output. The peak power from the 0.36 Hz sine-wave gust was 1.36% lower than that from the 0.56 Hz step gust. Ultimately, the study yielded new insights into VAWT aerodynamics, contributing to the advancement of turbine design and optimization of wind farm performance.

Authors

Institutions

Publication Details

Journal
Multiscale and Multidisciplinary Modeling Experiments and Design
Published
2026-02-12
DOI
https://doi.org/10.1007/s41939-025-01152-z
Primary Topic
Wind Energy Research and Development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on aerodynamic performances of the vertical-axis wind turbines under different wind gust configurations: comparative numerical modeling

Zakria G. Toor, Haitham M. S. Bahaidarah, Mohamed E. Zayed, Shafiqur Rehman
Multiscale and Multidisciplinary Modeling Experiments and Design
Wind Energy Research and Development
article

Research on aerodynamic performances of the vertical-axis wind turbines under different wind gust configurations: comparative numerical modeling

Zakria G. Toor, Haitham M. S. Bahaidarah, Mohamed E. Zayed, Shafiqur Rehman
article en

Abstract

Vertical Axis Wind Turbines (VAWT) offer a viable sustainable alternative, with improved efficiency at moderate to low wind speeds. However, the lower starting of VAWTS, with vibration and stability issues is still significant challenging for large-scale utilization development. The present work investigates the performance of a VAWT under different gust shapes (step and sine-wave) at steady and unsteady wind conditions. Computational Fluid Dynamics (CFD) simulations are performed to analyze the aerodynamic performance of the distinct VAWT prototype under varying wind gusts. The local wind data for Dhahran, Saudi Arabia, is used to identify the representative gust profiles and evaluate the wind turbine performance. Moreover, the effects of time period variation of the gust, gust frequency, and azimuthal angle on the wind turbine performance are also investigated. The study is also extended to compare the performance of the proposed wind gusts against a standard gust model defined by the International Electrotechnical Commission (IEC) to provide a better understanding of its dynamic response in actual wind gust conditions. The results demonstrated that as wind velocity during the gust increases, the effective tip speed ratio reduces, whereas the aerodynamic moment of the turbine increases. This increase is directly proportional to the amplitude of the gust. Unsteady simulations also revealed a coupled behavior between the wind velocity and wind turbine power coefficient. It is found that when the wind velocity during the gust increased by 12%, the turbine power coefficient increased by 12%, and the energy coefficient of the turbine reduced by 22%. A further analysis of three frequencies (0.36, 0.46, and 0.56 Hz) at constant amplitude showed that higher-frequency gusts cause faster wind changes, affecting dynamic stall and reducing power output. The peak power from the 0.36 Hz sine-wave gust was 1.36% lower than that from the 0.56 Hz step gust. Ultimately, the study yielded new insights into VAWT aerodynamics, contributing to the advancement of turbine design and optimization of wind farm performance.

Multiscale and Multidisciplinary Modeling Experiments and DesignVol. 9(1)
King Fahd University of Petroleum and Minerals (SA)
King Fahd University of Petroleum and Minerals
Openalex Percentile: Top 59%
Wind Energy Research and Development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.