Beyond Transconductance: Cell‐Polymer Coupling Determines Fidelity in Action Potential Recording via Electrolyte‐Gated Polymer Transistors

Organic bioelectronic transistors emerged as powerful tools for probing cellular electrophysiology, offering biocompatibility, mechanical softness, and operational stability in biological environments. Despite these advantages, device benchmarking focused so far exclusively on electrical figures of merit, leaving interfacial processes that contribute to signal recording fidelity largely unexplored. Poly[2-(3,3'-bis(2-(2-(2-methoxyethoxy)ethoxy)ethoxy)-[2,2'-bithiophen]-5-yl)thieno[3,2-b]thiophene] (p(g2T-TT)) is a model glycolated organic mixed ionic-electronic conductor, whose high transconductance and optimal volumetric field-effect behavior in physiological environment have been widely documented in Organic Electrochemical Transistor (OECT) configurations. Thus, p(g2T-TT)-based OECT was assessed as a promising candidate for recording action potentials (APs) from human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). Surprisingly, although AP signal transduction was observed, the recorded AP waveforms failed to reproduce the expected morphology, especially when compared to signals recorded via poly(3-hexylthiophene-2,5-diyl) (P3HT)-based Electrolyte-Gated Field-Effect Transistors (EGOFETs). Immunofluorescence imaging revealed improved adhesion on P3HT with respect to p(g2T-TT), suggesting weaker cell-device coupling as the underlying limitation. Our results show that not all polymers combining biocompatibility and high electrical performance can transduce AP signals with high-fidelity. Instead, interfacial properties govern bioelectronic transduction and provide a foundation for the rational design of polymers and platforms enabling reliable in vitro cellular electrophysiology, with potential translation to in vivo applications.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2026-02-12
DOI
https://doi.org/10.1002/advs.202520122
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Beyond Transconductance: Cell‐Polymer Coupling Determines Fidelity in Action Potential Recording via Electrolyte‐Gated Polymer Transistors

Shubham Tanwar, Gabriele Tullii, Adrica Kyndiah, Elena Mancinelli et al.
Advanced Science
Conducting polymers and applications
article

Beyond Transconductance: Cell‐Polymer Coupling Determines Fidelity in Action Potential Recording via Electrolyte‐Gated Polymer Transistors

Shubham Tanwar, Gabriele Tullii, Adrica Kyndiah, Elena Mancinelli, Aleksandr Khudiakov, Maria Rosa Antognazza, Cristiano Bortolotti, Luca Sala, Giulia Zoe Zemignani, Mario Caironi, Peter J. Schwartz
article en

Abstract

Organic bioelectronic transistors emerged as powerful tools for probing cellular electrophysiology, offering biocompatibility, mechanical softness, and operational stability in biological environments. Despite these advantages, device benchmarking focused so far exclusively on electrical figures of merit, leaving interfacial processes that contribute to signal recording fidelity largely unexplored. Poly[2-(3,3'-bis(2-(2-(2-methoxyethoxy)ethoxy)ethoxy)-[2,2'-bithiophen]-5-yl)thieno[3,2-b]thiophene] (p(g2T-TT)) is a model glycolated organic mixed ionic-electronic conductor, whose high transconductance and optimal volumetric field-effect behavior in physiological environment have been widely documented in Organic Electrochemical Transistor (OECT) configurations. Thus, p(g2T-TT)-based OECT was assessed as a promising candidate for recording action potentials (APs) from human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs). Surprisingly, although AP signal transduction was observed, the recorded AP waveforms failed to reproduce the expected morphology, especially when compared to signals recorded via poly(3-hexylthiophene-2,5-diyl) (P3HT)-based Electrolyte-Gated Field-Effect Transistors (EGOFETs). Immunofluorescence imaging revealed improved adhesion on P3HT with respect to p(g2T-TT), suggesting weaker cell-device coupling as the underlying limitation. Our results show that not all polymers combining biocompatibility and high electrical performance can transduce AP signals with high-fidelity. Instead, interfacial properties govern bioelectronic transduction and provide a foundation for the rational design of polymers and platforms enabling reliable in vitro cellular electrophysiology, with potential translation to in vivo applications.

Advanced Science
Italian Institute of Technology (IT), IRCCS Istituto Auxologico Italiano (IT), Center for Nano Science and Technology (IT), University of Milano-Bicocca (IT), Politecnico di Milano (IT)
Ministero dell'Università e della Ricerca
Openalex Percentile: Top 58%
Conducting polymers and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.