Multivariate analysis on simulated moisture damage emission to indoor air

Moisture damage in buildings is a significant source of indoor air problems, releasing e.g. volatile organic compounds (VOCs) and microbially produced VOCs (MVOCs), which can cause unpleasant odors and health symptoms. However, interpreting MVOCs as indicators of mold is challenging due to their various sources and limitations in analytical methods. The objective of this study was to identify the most critical factors influencing VOC emissions from moisture-damaged wall structures into the indoor environment via structural air leakages. The research was conducted using the VTT Indoor Air Quality (IAQ) Simulator and analyzed with Principal Component Analysis (PCA). The IAQ simulator was used to investigate the transport of airborne impurities from mold-contaminated wall structures in realistic building conditions and the systematic manipulation of key environmental parameters. The resulting dataset was subjected to multivariate analysis to identify the most influential factors contributing to IAQ degradation in moisture-damaged structures. The key conclusions revealed that material relative humidity was the most significant single factor affecting all VOC concentrations; higher humidity consistently increased emissions. Four specific ketones (2-pentanone, 2-hexanone, 2-heptanone, and 2-octanone) were clearly identified as originating from microbial growth, with their concentrations being significantly higher in the presence of active mold growth. Pressure differentials had only a borderline effect on gypsum board emissions, while the insulation layer showed no significant impact on any of the identified VOC components. These findings underscore the critical role of relative humidity in determining indoor VOC profiles and highlight the value of multivariate methods in assessing mold-related indoor air problems.

Authors

Institutions

Publication Details

Journal
The Science of The Total Environment
Published
2026-02-12
DOI
https://doi.org/10.1016/j.scitotenv.2026.181512
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multivariate analysis on simulated moisture damage emission to indoor air

Vuokko Lappalainen, Joonas Sorvari, Elina Sohlberg, P. Pasanen
The Science of The Total Environment
Indoor Air Quality and Microbial Exposure
article

Multivariate analysis on simulated moisture damage emission to indoor air

Vuokko Lappalainen, Joonas Sorvari, Elina Sohlberg, P. Pasanen
article en

Abstract

Moisture damage in buildings is a significant source of indoor air problems, releasing e.g. volatile organic compounds (VOCs) and microbially produced VOCs (MVOCs), which can cause unpleasant odors and health symptoms. However, interpreting MVOCs as indicators of mold is challenging due to their various sources and limitations in analytical methods. The objective of this study was to identify the most critical factors influencing VOC emissions from moisture-damaged wall structures into the indoor environment via structural air leakages. The research was conducted using the VTT Indoor Air Quality (IAQ) Simulator and analyzed with Principal Component Analysis (PCA). The IAQ simulator was used to investigate the transport of airborne impurities from mold-contaminated wall structures in realistic building conditions and the systematic manipulation of key environmental parameters. The resulting dataset was subjected to multivariate analysis to identify the most influential factors contributing to IAQ degradation in moisture-damaged structures. The key conclusions revealed that material relative humidity was the most significant single factor affecting all VOC concentrations; higher humidity consistently increased emissions. Four specific ketones (2-pentanone, 2-hexanone, 2-heptanone, and 2-octanone) were clearly identified as originating from microbial growth, with their concentrations being significantly higher in the presence of active mold growth. Pressure differentials had only a borderline effect on gypsum board emissions, while the insulation layer showed no significant impact on any of the identified VOC components. These findings underscore the critical role of relative humidity in determining indoor VOC profiles and highlight the value of multivariate methods in assessing mold-related indoor air problems.

The Science of The Total EnvironmentVol. 1019
University of Eastern Finland (FI), Natural Resources Institute Finland (FI), VTT Technical Research Centre of Finland (FI)
Sustainable cities and communities
Openalex Percentile: Top 60%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.