Dynamic Gait Stability Estimated Using One or Two Inertial Measurement Units Worn on the Human Body

The margin of stability (MoS) is a metric used to assess dynamic postural stability during walking. Although MoS is typically computed from optical motion capture data, previous studies have shown that MoS can be approximated from six-axis kinematic signals-linear acceleration and angular velocity-measured by inertial measurement units (IMUs). With IMU-equipped devices such as smartphones and smartwatches becoming widespread, it is increasingly common for individuals to carry two or more such devices in daily life. This study aimed to identify combinations of two body locations that most effectively predict MoS. IMU sensors were attached to ten body locations while participants walked on a treadmill. Principal motion analysis, a reductive regression method for multidimensional time-series data, was employed for MoS prediction, and cross-validation was used for reliable model evaluation. Appropriate combinations of two IMU sensors achieved mean errors of approximately 30 mm and 11 mm in anterior and mediolateral MoS, respectively, compared with reference values derived from optical motion capture. These errors were comparable to the intrinsic standard deviations of MoS, suggesting that IMU-based MoS estimation is sufficiently accurate for the classification of individuals at high fall risk.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-02-12
DOI
https://doi.org/10.3390/s26041211
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Gait Stability Estimated Using One or Two Inertial Measurement Units Worn on the Human Body

Shogo OKAMOTO, Hiroki Watanabe, Yasuhiro AKIYAMA, Haoyun Peng
Sensors
Balance, Gait, and Falls Prevention
article

Dynamic Gait Stability Estimated Using One or Two Inertial Measurement Units Worn on the Human Body

Shogo OKAMOTO, Hiroki Watanabe, Yasuhiro AKIYAMA, Haoyun Peng
article en

Abstract

The margin of stability (MoS) is a metric used to assess dynamic postural stability during walking. Although MoS is typically computed from optical motion capture data, previous studies have shown that MoS can be approximated from six-axis kinematic signals-linear acceleration and angular velocity-measured by inertial measurement units (IMUs). With IMU-equipped devices such as smartphones and smartwatches becoming widespread, it is increasingly common for individuals to carry two or more such devices in daily life. This study aimed to identify combinations of two body locations that most effectively predict MoS. IMU sensors were attached to ten body locations while participants walked on a treadmill. Principal motion analysis, a reductive regression method for multidimensional time-series data, was employed for MoS prediction, and cross-validation was used for reliable model evaluation. Appropriate combinations of two IMU sensors achieved mean errors of approximately 30 mm and 11 mm in anterior and mediolateral MoS, respectively, compared with reference values derived from optical motion capture. These errors were comparable to the intrinsic standard deviations of MoS, suggesting that IMU-based MoS estimation is sufficiently accurate for the classification of individuals at high fall risk.

SensorsVol. 26(4)
Shinshu University (JP), Tokyo Metropolitan University (JP)
Openalex Percentile: Top 60%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.