Initial-contact-timing Estimation Based on Supervised Learning in a Hip-assistive Wearable Robot

Hip-assistive wearable robots have been widely adopted for gait rehabilitation due to their lightweight design and ease of use. However, the lack of distal sensors, such as shank inertial measurement units (IMUs) or foot pressure insoles, limits precise gait event detection. This study proposes an initial contact (IC) estimation method using only thigh angle measurements and two IMU signals embedded in a hip-assistive robot. The algorithm was validated against IC timings obtained from foot pressure sensors. Using a k-nearest neighbors model trained on kinematic features around IC, the method accurately detected IC events and demonstrated high agreement with the reference data. Moreover, the model achieved a root mean squared error of 2.20% ± 1.15%. These results demonstrate that reliable IC estimation and spatiotemporal gait analysis can be achieved using only hip-embedded sensors, without additional distal instrumentation.

Authors

Publication Details

Journal
Journal of Institute of Control Robotics and Systems
Published
2026-02-12
DOI
https://doi.org/10.5302/j.icros.2026.25.0300
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Initial-contact-timing Estimation Based on Supervised Learning in a Hip-assistive Wearable Robot

Jung-Hee Jo, Hyunjin Choi, Seon-Min Koo
Journal of Institute of Control Robotics and Systems
Prosthetics and Rehabilitation Robotics
article

Initial-contact-timing Estimation Based on Supervised Learning in a Hip-assistive Wearable Robot

Jung-Hee Jo, Hyunjin Choi, Seon-Min Koo
article en

Abstract

Hip-assistive wearable robots have been widely adopted for gait rehabilitation due to their lightweight design and ease of use. However, the lack of distal sensors, such as shank inertial measurement units (IMUs) or foot pressure insoles, limits precise gait event detection. This study proposes an initial contact (IC) estimation method using only thigh angle measurements and two IMU signals embedded in a hip-assistive robot. The algorithm was validated against IC timings obtained from foot pressure sensors. Using a k-nearest neighbors model trained on kinematic features around IC, the method accurately detected IC events and demonstrated high agreement with the reference data. Moreover, the model achieved a root mean squared error of 2.20% ± 1.15%. These results demonstrate that reliable IC estimation and spatiotemporal gait analysis can be achieved using only hip-embedded sensors, without additional distal instrumentation.

Journal of Institute of Control Robotics and SystemsVol. 32(2)
Openalex Percentile: Top 58%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.