The diagnostic value of transfistular contrast-enhanced ultrasound in branchial cleft fistulas

Among the enrolled 35 patients, 29 were surgically confirmed as BCF. Postoperative surgical findings served as the reference standard for all analyses. Transfistular CEUS demonstrated superior diagnostic accuracy compared to 2D-US for BCF detection (91.4% vs. 82.9%). Excellent agreement was observed between CEUS and surgical findings in internal orifice localization (κ=0.814, p<0.001). For BCF classification, the accuracy, sensitivity, and specificity of transfistular CEUS were as follows: type I BCF (93.1%, 93.8%, 92.3%), type II BCF (89.7%, 71.4%, 91.3%), and pyriform fossa fistulas (96.6%, 100.0%, and 95.7%), respectively. Conclusions: As a radiation-free, cost-effective, and non-invasive technique, transfistular CEUS can accurately diagnose BCF, precisely localize its internal orifice, and effectively differentiate its subtypes. For patients clinically suspected of BCF, transfistular CEUS is a reliable preoperative tool for individualized clinical guidance.

Authors

Institutions

Publication Details

Journal
Medical Ultrasonography
Published
2026-02-12
DOI
https://doi.org/10.11152/mu-4587
Primary Topic
Head and Neck Anomalies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The diagnostic value of transfistular contrast-enhanced ultrasound in branchial cleft fistulas

Jiangyan Yin, Quan Zeng, Wenqi Zuo, Yawen Chen et al.
Medical Ultrasonography
Head and Neck Anomalies
article

The diagnostic value of transfistular contrast-enhanced ultrasound in branchial cleft fistulas

Jiangyan Yin, Quan Zeng, Wenqi Zuo, Yawen Chen, Xuemei He
article en

Abstract

Among the enrolled 35 patients, 29 were surgically confirmed as BCF. Postoperative surgical findings served as the reference standard for all analyses. Transfistular CEUS demonstrated superior diagnostic accuracy compared to 2D-US for BCF detection (91.4% vs. 82.9%). Excellent agreement was observed between CEUS and surgical findings in internal orifice localization (κ=0.814, p<0.001). For BCF classification, the accuracy, sensitivity, and specificity of transfistular CEUS were as follows: type I BCF (93.1%, 93.8%, 92.3%), type II BCF (89.7%, 71.4%, 91.3%), and pyriform fossa fistulas (96.6%, 100.0%, and 95.7%), respectively. Conclusions: As a radiation-free, cost-effective, and non-invasive technique, transfistular CEUS can accurately diagnose BCF, precisely localize its internal orifice, and effectively differentiate its subtypes. For patients clinically suspected of BCF, transfistular CEUS is a reliable preoperative tool for individualized clinical guidance.

Medical Ultrasonography
The Affiliated Yongchuan Hospital of Chongqing Medical University (CN), Chongqing Medical University (CN)
Chongqing Medical University
Openalex Percentile: Top 59%
Head and Neck Anomalies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.