Breast phantom enhancement: Taguchi-type optimization for CT scan imaging quality and additive manufacturing realization

An indigenous breast phantom was customized to optimize the imaging quality of the CT scan according to Taguchi's methodology. A 3D printer made the base gauge of the breast phantom, and the polysmooth<sup>TM</sup> filament was sprayed. The gauge can be categorized into three major parts vertical and horizontal line pairs, two V-shape slices, and two arrays of nodules with various sizes, then a spherical shell mad by paraffin casting and the sunflower oil was infused as filling material. The Taguchi approach led to the development of a customized measuring device that enabled quantitative assessment aimed at improving the spatial resolution of CT image quality. Five essential factors for operating the CT chest scan (kVp, mAs, FOV, Pitch, and gantry rotation time) were organized according to Taguchi L<sub>18</sub>(2<sup>1</sup> × 3<sup>4</sup>) suggestion. Three well-trained radiologists ranked the imaging quality in three discrete time periods according to the imaging quality's sharpness, contrast, and spatial resolution. The derived average, standard deviation, and signal-to-noise ratio of specific factors were reorganized and analyzed from the multiple measurements to propose the optimal CT chest scan protocol recommendation. Accordingly, the optimal suggestion was A1(120 kVp), B3(200 mAs), C2(FOV 350 mm<sup>2</sup>), D1(pitch 0.516) and E2(rotation time 0.75 s) to fulfill the ALARA principle. In this research, a numerical metric termed the minimum detectable difference (MDD) was introduced to evaluate imaging performance, and its calculated value demonstrated a resolution capability of approximately 1.57 mm.

Authors

Institutions

Publication Details

Journal
Technology and Health Care
Published
2026-02-12
DOI
https://doi.org/10.1177/09287329261417465
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Breast phantom enhancement: Taguchi-type optimization for CT scan imaging quality and additive manufacturing realization

Fu-Tsai Chiang, Chun-Chieh Liang, K. Y. Cheng, Lung-Fa Pan et al.
Technology and Health Care
Digital Radiography and Breast Imaging
article

Breast phantom enhancement: Taguchi-type optimization for CT scan imaging quality and additive manufacturing realization

Fu-Tsai Chiang, Chun-Chieh Liang, K. Y. Cheng, Lung-Fa Pan, Samrit Kittipayak, Ching-Hsiu Ke, Jia-Hua Hsu, Ying-Liang Chou, Lung-Kwang Pan
article en

Abstract

An indigenous breast phantom was customized to optimize the imaging quality of the CT scan according to Taguchi's methodology. A 3D printer made the base gauge of the breast phantom, and the polysmooth<sup>TM</sup> filament was sprayed. The gauge can be categorized into three major parts vertical and horizontal line pairs, two V-shape slices, and two arrays of nodules with various sizes, then a spherical shell mad by paraffin casting and the sunflower oil was infused as filling material. The Taguchi approach led to the development of a customized measuring device that enabled quantitative assessment aimed at improving the spatial resolution of CT image quality. Five essential factors for operating the CT chest scan (kVp, mAs, FOV, Pitch, and gantry rotation time) were organized according to Taguchi L<sub>18</sub>(2<sup>1</sup> × 3<sup>4</sup>) suggestion. Three well-trained radiologists ranked the imaging quality in three discrete time periods according to the imaging quality's sharpness, contrast, and spatial resolution. The derived average, standard deviation, and signal-to-noise ratio of specific factors were reorganized and analyzed from the multiple measurements to propose the optimal CT chest scan protocol recommendation. Accordingly, the optimal suggestion was A1(120 kVp), B3(200 mAs), C2(FOV 350 mm<sup>2</sup>), D1(pitch 0.516) and E2(rotation time 0.75 s) to fulfill the ALARA principle. In this research, a numerical metric termed the minimum detectable difference (MDD) was introduced to evaluate imaging performance, and its calculated value demonstrated a resolution capability of approximately 1.57 mm.

Technology and Health Care
Ministry of Health and Welfare (KR), Chulabhorn Hospital (TH), Taichung Hospital (TW), Taichung Armed Forces General Hospital (TW), Changhua Christian Hospital (TW), National Defense Medical Center (TW), Central Taiwan University of Science and Technology (TW)
Industry, innovation and infrastructure
Openalex Percentile: Top 60%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.