Green and rapid magnetic solid-phase extraction coupled with HPLC-UV for sensitive detection of multiple statins in tea-based functional foods

The illegal addition of statins to tea-based products presents significant analytical challenges due to the complexity of the matrices involved. To address these challenges, we developed an ionic liquid-assisted magnetic solid-phase extraction (IL-MSPE) method coupled with HPLC-UV for the simultaneous determination of five statins. This protocol facilitates the rapid batch extraction of analytes within six minutes. The method demonstrated excellent linearity (R 2 ≥0.999, 0.1 to 20 μg/mL) and sensitivity, with limits of detection ranging from 0.022 to 0.054 μg/mL, and recovery rates between 89.2% and 117.5%. Density functional theory provided insights into a synergistic “dual-site” recognition mechanism, which is driven by π–π stacking, hydrogen bonding, and electrostatic interactions. Importantly, the method's compliance with green chemistry principles was validated by AGREE (0.77) and MoGAPI (90) metrics. Overall, this proposed workflow represents a reliable and high-throughput tool for monitoring unauthorized statin adulteration. • Novel IL-MSPE-HPLC-UV method detects five statins in tea-based functional foods. • Rapid batch extraction is achieved within 6 min with high throughput capacity. • DFT calculations elucidate a synergistic “dual-site” recognition mechanism. • Sustainability is rigorously confirmed by AGREE, MoGAPI, and four other metrics. • The protocol offers a robust tool for monitoring unauthorized statin adulteration.

Authors

Institutions

Publication Details

Journal
LWT
Published
2026-02-13
DOI
https://doi.org/10.1016/j.lwt.2026.119148
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Green and rapid magnetic solid-phase extraction coupled with HPLC-UV for sensitive detection of multiple statins in tea-based functional foods

Yulin Hou, Jinghui Du, Yue Xing, Jiejin SONG et al.
LWT
Pesticide Residue Analysis and Safety
article

Green and rapid magnetic solid-phase extraction coupled with HPLC-UV for sensitive detection of multiple statins in tea-based functional foods

Yulin Hou, Jinghui Du, Yue Xing, Jiejin SONG, jian gao, Fengchao Wang, Liming Wang, Jiang Wu, Jialong Wang
article en

Abstract

The illegal addition of statins to tea-based products presents significant analytical challenges due to the complexity of the matrices involved. To address these challenges, we developed an ionic liquid-assisted magnetic solid-phase extraction (IL-MSPE) method coupled with HPLC-UV for the simultaneous determination of five statins. This protocol facilitates the rapid batch extraction of analytes within six minutes. The method demonstrated excellent linearity (R 2 ≥0.999, 0.1 to 20 μg/mL) and sensitivity, with limits of detection ranging from 0.022 to 0.054 μg/mL, and recovery rates between 89.2% and 117.5%. Density functional theory provided insights into a synergistic “dual-site” recognition mechanism, which is driven by π–π stacking, hydrogen bonding, and electrostatic interactions. Importantly, the method's compliance with green chemistry principles was validated by AGREE (0.77) and MoGAPI (90) metrics. Overall, this proposed workflow represents a reliable and high-throughput tool for monitoring unauthorized statin adulteration. • Novel IL-MSPE-HPLC-UV method detects five statins in tea-based functional foods. • Rapid batch extraction is achieved within 6 min with high throughput capacity. • DFT calculations elucidate a synergistic “dual-site” recognition mechanism. • Sustainability is rigorously confirmed by AGREE, MoGAPI, and four other metrics. • The protocol offers a robust tool for monitoring unauthorized statin adulteration.

LWTVol. 243
Tianjin University of Traditional Chinese Medicine (CN), Xiyuan Hospital (CN), First Teaching Hospital of Tianjin University of Traditional Chinese Medicine (CN), China Academy of Chinese Medical Sciences (CN), Shenzhen Technology University (CN)
Responsible consumption and production
Openalex Percentile: Top 56%
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.