Dual Chamber Aveir Retrievable Leadless Pacemaker Implant in a Patient with a Senning Baffle and Subcutaneous ICD

Patients with dextro-transposition (D-TGA) of the great arteries and Senning or Mustard baffles have risk of sinus node dysfunction as well as ventricular arrhythmias. We demonstrate the implantation of a dual-chamber leadless pacemaker in a patient with a Senning baffle and symptomatic bradycardia, in the setting of a primary prevention subcutaneous internal cardioverter defibrillator (SQICD). A retrospective review of a case of dual chamber leadless pacemaker (Aveir DR) implant was performed including atrial baffle and left ventricular septal implant. A 41-year-old female with history of D-TGA and prior defibrillator, post-lead extraction and SQICD placement, after lead malfunction, presented with symptomatic bradycardia. She underwent a dual-chamber leadless pacemaker implant under echocardiographic guidance without complication. At 6-month follow-up, the atrial and ventricular thresholds were 0.5 [email protected] and 0.75 [email protected], with impedances of 350 ohms, and 730 ohms, respectively, with an R-wave of 17.3milliVolts. With 99% atrial pacing, and 15% ventricular pacing, the predicted longevity was 13.0 and 18.3 years for atrial and ventricular devices, respectively. No oversensing was noted on the subcutaneous ICD. The patient noted improved activity tolerance and no further presyncope. Successful implantation of a dual-chamber leadless pacemaker can be achieved in the LV septum of a patient with a Senning baffle and previously installed SICD.

Authors

Institutions

Publication Details

Journal
Pediatric Cardiology
Published
2026-02-12
DOI
https://doi.org/10.1007/s00246-026-04183-6
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual Chamber Aveir Retrievable Leadless Pacemaker Implant in a Patient with a Senning Baffle and Subcutaneous ICD

C. Raymond Bingham, Daniel Cortez
Pediatric Cardiology
Cardiac pacing and defibrillation studies
article

Dual Chamber Aveir Retrievable Leadless Pacemaker Implant in a Patient with a Senning Baffle and Subcutaneous ICD

C. Raymond Bingham, Daniel Cortez
article en

Abstract

Patients with dextro-transposition (D-TGA) of the great arteries and Senning or Mustard baffles have risk of sinus node dysfunction as well as ventricular arrhythmias. We demonstrate the implantation of a dual-chamber leadless pacemaker in a patient with a Senning baffle and symptomatic bradycardia, in the setting of a primary prevention subcutaneous internal cardioverter defibrillator (SQICD). A retrospective review of a case of dual chamber leadless pacemaker (Aveir DR) implant was performed including atrial baffle and left ventricular septal implant. A 41-year-old female with history of D-TGA and prior defibrillator, post-lead extraction and SQICD placement, after lead malfunction, presented with symptomatic bradycardia. She underwent a dual-chamber leadless pacemaker implant under echocardiographic guidance without complication. At 6-month follow-up, the atrial and ventricular thresholds were 0.5 [email protected] and 0.75 [email protected], with impedances of 350 ohms, and 730 ohms, respectively, with an R-wave of 17.3milliVolts. With 99% atrial pacing, and 15% ventricular pacing, the predicted longevity was 13.0 and 18.3 years for atrial and ventricular devices, respectively. No oversensing was noted on the subcutaneous ICD. The patient noted improved activity tolerance and no further presyncope. Successful implantation of a dual-chamber leadless pacemaker can be achieved in the LV septum of a patient with a Senning baffle and previously installed SICD.

Pediatric Cardiology
Davidson College (US), University of California Davis Medical Center (US)
University of California, Davis
Good health and well-being
Openalex Percentile: Top 60%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.