Transition-Edge Sensor Characteristics in a Modified Bias Circuit for Multiplexed Readout

The X-ray Integral Field Unit (X-IFU) on the NewAthena X-ray telescope will use a 1,504-pixel array of transition-edge sensor (TES) microcalorimeters, read out via time division multiplexing (TDM). To allow testing of multiplexer chips before TES integration, each unit cell includes a “TES-bypass” resistor that substitutes for a TES during characterization. After integration, this resistor remains as a high-resistance shunt: minimal for DC operation but can influence the frequency response due to its placement with the Nyquist inductor. We modeled the modified bias circuit, derived the small-signal response, and evaluated noise contributions, including Johnson noise from the bypass resistor. We analyzed the effects on pulse height, slew-rate, and energy resolution. Simulations were compared with measurements from prototype X-IFU microcalorimeters. Our results indicate that as long as the resistor value exceeds the TES dynamic resistance, performance is largely unaffected.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Applied Superconductivity
Published
2026-02-12
DOI
https://doi.org/10.1109/tasc.2026.3664193
Primary Topic
Superconducting and THz Device Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transition-Edge Sensor Characteristics in a Modified Bias Circuit for Multiplexed Readout

Stephen J Smith, Joshua D. Fuhrman, Malcolm Durkin, Christian Kirsch et al.
IEEE Transactions on Applied Superconductivity
Superconducting and THz Device Technology
article

Transition-Edge Sensor Characteristics in a Modified Bias Circuit for Multiplexed Readout

Stephen J Smith, Joshua D. Fuhrman, Malcolm Durkin, Christian Kirsch, Tannaz Farrahi, E. J. Wassell, F. M. Finkbeiner, J. S. Adams, Samuel V. Hull, H. Muramatsu, Paul van der Hulst, Nicholas A. Wakeham, Edoardo Cucchetti, M. C. Witthoeft, Sang H. Yoon, Meng P. Chiao, Joel Ullom, Ambarish C. Venkatasubraman, R. L. Kelley, C. A. Kilbourne, S. R. Bandler, J. A. Chervenak, W. Bertrand Doriese
article en

Abstract

The X-ray Integral Field Unit (X-IFU) on the NewAthena X-ray telescope will use a 1,504-pixel array of transition-edge sensor (TES) microcalorimeters, read out via time division multiplexing (TDM). To allow testing of multiplexer chips before TES integration, each unit cell includes a “TES-bypass” resistor that substitutes for a TES during characterization. After integration, this resistor remains as a high-resistance shunt: minimal for DC operation but can influence the frequency response due to its placement with the Nyquist inductor. We modeled the modified bias circuit, derived the small-signal response, and evaluated noise contributions, including Johnson noise from the bypass resistor. We analyzed the effects on pulse height, slew-rate, and energy resolution. Simulations were compared with measurements from prototype X-IFU microcalorimeters. Our results indicate that as long as the resistor value exceeds the TES dynamic resistance, performance is largely unaffected.

IEEE Transactions on Applied SuperconductivityVol. 36(6)
Goddard Space Flight Center (US), National Institute of Standards and Technology (US), Centre National d'Études Spatiales (FR), National Aeronautics and Space Administration (US), Space Research Organisation Netherlands (NL), University of Bamberg (DE)
Affordable and clean energy
Openalex Percentile: Top 56%
Superconducting and THz Device Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.