Performance Benchmarking for Thermal Modulators in Comprehensive Two-Dimensional Gas Chromatography: Evaluation of the Solid-State Modulator

The recently introduced solid-state modulator (SSM) is a compact and relatively simple all-in-one solution to thermal modulation for use in comprehensive two-dimensional gas chromatography (GC×GC). In this work, we assess the performance of this modulator through a detailed assessment of its temperature stability and temperature programming capabilities, and corresponding retention time reproducibility. Through replicate analysis, 2D retention time standard deviation was determined to be 0.014 s (ranging from 0.000–0.023 s), corresponding to less than a single acquisition datapoint. Additionally, 1D retention time repeatability in GC×GC was assessed using a ‘super-resolution method’ designed to predict 1D retention based on the modulated peak distribution, and was determined to be comparable to that of conventional GC-MS analysis. A benchmarking framework was developed, which can be applied to future performance evaluations of thermal and other modulators, allowing for a more systematic comparison of modulation strategies.

Authors

Institutions

Publication Details

Journal
Separations
Published
2026-02-12
DOI
https://doi.org/10.3390/separations13020065
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Benchmarking for Thermal Modulators in Comprehensive Two-Dimensional Gas Chromatography: Evaluation of the Solid-State Modulator

Jason Devers, Philip J. Marriott
Separations
Analytical Chemistry and Chromatography
article

Performance Benchmarking for Thermal Modulators in Comprehensive Two-Dimensional Gas Chromatography: Evaluation of the Solid-State Modulator

Jason Devers, Philip J. Marriott
article en

Abstract

The recently introduced solid-state modulator (SSM) is a compact and relatively simple all-in-one solution to thermal modulation for use in comprehensive two-dimensional gas chromatography (GC×GC). In this work, we assess the performance of this modulator through a detailed assessment of its temperature stability and temperature programming capabilities, and corresponding retention time reproducibility. Through replicate analysis, 2D retention time standard deviation was determined to be 0.014 s (ranging from 0.000–0.023 s), corresponding to less than a single acquisition datapoint. Additionally, 1D retention time repeatability in GC×GC was assessed using a ‘super-resolution method’ designed to predict 1D retention based on the modulated peak distribution, and was determined to be comparable to that of conventional GC-MS analysis. A benchmarking framework was developed, which can be applied to future performance evaluations of thermal and other modulators, allowing for a more systematic comparison of modulation strategies.

SeparationsVol. 13(2)
University of Copenhagen (DK), Australian Regenerative Medicine Institute (AU), Monash University (AU)
Openalex Percentile: Top 60%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Benchmarking for Thermal Modulators in Comprehensive Two-Dimensional Gas Chromatography: Evaluation of the Solid-State Modulator — Jason Devers, Philip J. Marriott · Separations (2026) | TGRS Research Map | TGRS