A Polymethyl Methacrylate Bone Cement With Reduced Stress Concentration

ABSTRACT Polymethyl methacrylate (PMMA) bone cement is the earliest and most widely used in clinical applications. However, PMMA bone cement has high hardness and high modulus, which leads to secondary fracture of adjacent vertebrae. In this study, a PMMA/polylactic acid (PLA)/carbon nanotube (CNT) compound bone cement with decreased compression modulus is developed for overcoming the limitation of PMMA commercial bone cement (CBC). Compared with CBC, the compression modulus of composite PMMA/PLA/CNT bone cements is reduced from 893.34 MPa (CBC) to 487.25 MPa (54.54% of the CBC), which is beneficial for reducing stress concentration at the bone implantation site. The cytotoxicity studies also indicate that the prepared composite cements are nontoxic and harmless, which has the necessary condition for orthopedic clinical applications.

Authors

Institutions

Publication Details

Journal
Electron
Published
2026-02-01
DOI
https://doi.org/10.1002/elt2.70032
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Polymethyl Methacrylate Bone Cement With Reduced Stress Concentration

Shuang Zhou, Quan Li, Zhengxue Quan, Yupei Han et al.
Electron
Bone Tissue Engineering Materials
article

A Polymethyl Methacrylate Bone Cement With Reduced Stress Concentration

Shuang Zhou, Quan Li, Zhengxue Quan, Yupei Han, Zhidong Cao, Lei Peng, Yunfa Dong
article en

Abstract

ABSTRACT Polymethyl methacrylate (PMMA) bone cement is the earliest and most widely used in clinical applications. However, PMMA bone cement has high hardness and high modulus, which leads to secondary fracture of adjacent vertebrae. In this study, a PMMA/polylactic acid (PLA)/carbon nanotube (CNT) compound bone cement with decreased compression modulus is developed for overcoming the limitation of PMMA commercial bone cement (CBC). Compared with CBC, the compression modulus of composite PMMA/PLA/CNT bone cements is reduced from 893.34 MPa (CBC) to 487.25 MPa (54.54% of the CBC), which is beneficial for reducing stress concentration at the bone implantation site. The cytotoxicity studies also indicate that the prepared composite cements are nontoxic and harmless, which has the necessary condition for orthopedic clinical applications.

ElectronVol. 4(1)
Harbin Institute of Technology (CN), Chongqing Academy of Science and Technology (CN), The Affiliated Yongchuan Hospital of Chongqing Medical University (CN), Chongqing Emergency Medical Center (CN), University College London (GB), Chongqing Medical University (CN)
Openalex Percentile: Top 59%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.