Laparoscopic Acetabular Plate Fixation: A Cadaveric Feasibility Study for Technique Development

This technical note describe the feasibility of a reproducible laparoscopic technique for acetabular fracture fixation, focusing on the feasibility of using infra-pectineal and supra-pectineal plates and proper screw placement. A standardized preperitoneal laparoscopic approach was performed on ten adult cadavers. Infra-pectineal and supra-pectineal plates were inserted under laparoscopic control, and screw placement was guided using an eight-zone pelvic classification. Feasibility criteria included exposure quality, implant positioning, operative time, and complications. The procedure was successfully completed in 9 of 10 specimens (90%). Key anatomical landmarks were consistently identified. All implants were positioned as planned. Mean operative time was 115 min (range 90-120), with no major vascular, visceral, or neurological injuries. This technique appears feasible and reproducible and may offer a minimally invasive alternative for selected acetabular fractures, particularly in fragile patients. LEVEL OF EVIDENCE: IV; cadaveric study.

Authors

Institutions

Publication Details

Journal
Orthopaedics & Traumatology Surgery & Research
Published
2026-02-01
DOI
https://doi.org/10.1016/j.otsr.2026.104639
Primary Topic
Pelvic and Acetabular Injuries
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laparoscopic Acetabular Plate Fixation: A Cadaveric Feasibility Study for Technique Development

Clément Marc, Florian Bernard, Vincent Steiger, Nathan Milliot et al.
Orthopaedics & Traumatology Surgery & Research
Pelvic and Acetabular Injuries
article

Laparoscopic Acetabular Plate Fixation: A Cadaveric Feasibility Study for Technique Development

Clément Marc, Florian Bernard, Vincent Steiger, Nathan Milliot, Louis Rony, Guillaume David
article en

Abstract

This technical note describe the feasibility of a reproducible laparoscopic technique for acetabular fracture fixation, focusing on the feasibility of using infra-pectineal and supra-pectineal plates and proper screw placement. A standardized preperitoneal laparoscopic approach was performed on ten adult cadavers. Infra-pectineal and supra-pectineal plates were inserted under laparoscopic control, and screw placement was guided using an eight-zone pelvic classification. Feasibility criteria included exposure quality, implant positioning, operative time, and complications. The procedure was successfully completed in 9 of 10 specimens (90%). Key anatomical landmarks were consistently identified. All implants were positioned as planned. Mean operative time was 115 min (range 90-120), with no major vascular, visceral, or neurological injuries. This technique appears feasible and reproducible and may offer a minimally invasive alternative for selected acetabular fractures, particularly in fragile patients. LEVEL OF EVIDENCE: IV; cadaveric study.

Orthopaedics & Traumatology Surgery & Research
Centre Hospitalier Universitaire d'Angers (FR), Laboratoire Angevin de Recherche en Mathématiques (FR), Université d'Angers (FR)
Openalex Percentile: Top 59%
Pelvic and Acetabular Injuries
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laparoscopic Acetabular Plate Fixation: A Cadaveric Feasibility Study for Technique Development — Clément Marc, Florian Bernard, et al. · Orthopaedics & Traumatology Surgery & Research (2026) | TGRS Research Map | TGRS