Development of a High‐Throughput LC–MS/MS Method for Simultaneous Quantification of Four Therapeutic Monoclonal Antibodies in Human Serum: Application in Clinical Therapeutic Drug Monitoring

Monoclonal antibody (mAb) therapies have revolutionized cancer treatment, significantly improving patient outcomes. However, the pharmacokinetics (PK) and pharmacodynamics (PD) of mAbs exhibit considerable variability due to nonlinear kinetics and individual differences, highlighting the need for therapeutic drug monitoring (TDM). Therefore, this study aimed to develop and validate a reliable LC-MS/MS method for the simultaneous quantification of bevacizumab, trastuzumab, rituximab, and pertuzumab in human serum and evaluate its clinical applicability. Characteristic peptides were identified using Skyline. Serum samples underwent Protein G purification and trypsin digestion. Separation used a C18 column with 0.1% FA and acetonitrile, and detection employed multiple reaction monitoring with cadonilimab as the internal standard. The method demonstrated excellent linearity (1-200 μg/mL), precision (CV < 8.9%), and accuracy (±9.8%). With a runtime of 12 min, the validated method requires only 10 μL of serum per sample and meets international validation standards, supporting the clinical monitoring of these therapies. A robust, cost-effective, and high-throughput LC-MS/MS method was successfully developed for the simultaneous quantification of four therapeutic mAbs. The method significantly reduces sample volume and analysis time while maintaining high accuracy and reproducibility, making it well-suited for routine TDM and broader clinical applications.

Authors

Institutions

Publication Details

Journal
Biomedical Chromatography
Published
2026-02-11
DOI
https://doi.org/10.1002/bmc.70350
Primary Topic
Monoclonal and Polyclonal Antibodies Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a High‐Throughput LC–MS/MS Method for Simultaneous Quantification of Four Therapeutic Monoclonal Antibodies in Human Serum: Application in Clinical Therapeutic Drug Monitoring

Tianmin Wu, Junping Wang, Guang‐Yao Huang, Ting‐Fei Tan et al.
Biomedical Chromatography
Monoclonal and Polyclonal Antibodies Research
article

Development of a High‐Throughput LC–MS/MS Method for Simultaneous Quantification of Four Therapeutic Monoclonal Antibodies in Human Serum: Application in Clinical Therapeutic Drug Monitoring

Tianmin Wu, Junping Wang, Guang‐Yao Huang, Ting‐Fei Tan, Chao Huang, Yuan Yao, Shan Gao, Feng‐Mei Hu, An‐Ping Guo
article en

Abstract

Monoclonal antibody (mAb) therapies have revolutionized cancer treatment, significantly improving patient outcomes. However, the pharmacokinetics (PK) and pharmacodynamics (PD) of mAbs exhibit considerable variability due to nonlinear kinetics and individual differences, highlighting the need for therapeutic drug monitoring (TDM). Therefore, this study aimed to develop and validate a reliable LC-MS/MS method for the simultaneous quantification of bevacizumab, trastuzumab, rituximab, and pertuzumab in human serum and evaluate its clinical applicability. Characteristic peptides were identified using Skyline. Serum samples underwent Protein G purification and trypsin digestion. Separation used a C18 column with 0.1% FA and acetonitrile, and detection employed multiple reaction monitoring with cadonilimab as the internal standard. The method demonstrated excellent linearity (1-200 μg/mL), precision (CV < 8.9%), and accuracy (±9.8%). With a runtime of 12 min, the validated method requires only 10 μL of serum per sample and meets international validation standards, supporting the clinical monitoring of these therapies. A robust, cost-effective, and high-throughput LC-MS/MS method was successfully developed for the simultaneous quantification of four therapeutic mAbs. The method significantly reduces sample volume and analysis time while maintaining high accuracy and reproducibility, making it well-suited for routine TDM and broader clinical applications.

Biomedical ChromatographyVol. 40(3)
University of Science and Technology of China (CN), Anhui Medical University (CN), Hefei Institutes of Physical Science (CN), Anhui Provincial Hospital (CN), Shanghai Optical Instrument Research Institute (CN)
Chinese Academy of Sciences, Hefei Institutes of Physical Science, Chinese Academy of Sciences
Openalex Percentile: Top 59%
Monoclonal and Polyclonal Antibodies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.