Exergy Analysis for Evaluating the Performance of an Integrated Leachate Treatment System

Exergy analysis provides a unified framework for assessing environmental, technical, and economic aspects in energy terms, enabling the identification of irreversibilities that reduce process efficiency. In wastewater treatment, its application remains limited, focusing on municipal effluents and chemical exergy derived from chemical oxygen demand. This study proposes an advanced exergy analysis model for wastewater treatment, structured in three phases: (i) system data, (ii) exergy analysis, and (iii) optimization through exergoenvironmental, exergoeconomic, and exergotechnical indicators, statistically assessed using the desirability function approach (DFA). The model was validated using a case study of a leachate treatment system that combined coagulation-flocculation, three photo-Fenton configurations, and activated sludge. The highest desirability (0.59) in exergy terms for the pretreatment was achieved with 1 g L<sup>-1</sup> iron chloride at pH 5, while DFA was 0.74 in the photo-Fenton process involved pretreated leachate with residual iron (0.08 g L<sup>-1</sup> of iron) and a single 2.5 g L<sup>-1</sup> dose of hydrogen peroxide followed by biological treatment. Irreversibilities were greatest in the biological stage due to electricity demand followed by influent composition, reagent consumption, and sludge generation. The model offers robust criteria for optimizing treatment design and supports the achievement of Sustainable Development Goals 6, 11, and 12.

Authors

Institutions

Publication Details

Journal
Water Environment Research
Published
2026-02-01
DOI
https://doi.org/10.1002/wer.70306
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exergy Analysis for Evaluating the Performance of an Integrated Leachate Treatment System

Ricardo L. Mejía‐Marchena, Salvador Villamizar, Joseph Soto‐Verjel, Aymer Maturana‐Cordoba et al.
Water Environment Research
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Exergy Analysis for Evaluating the Performance of an Integrated Leachate Treatment System

Ricardo L. Mejía‐Marchena, Salvador Villamizar, Joseph Soto‐Verjel, Aymer Maturana‐Cordoba, Angelo Soto‐Vergel
article en

Abstract

Exergy analysis provides a unified framework for assessing environmental, technical, and economic aspects in energy terms, enabling the identification of irreversibilities that reduce process efficiency. In wastewater treatment, its application remains limited, focusing on municipal effluents and chemical exergy derived from chemical oxygen demand. This study proposes an advanced exergy analysis model for wastewater treatment, structured in three phases: (i) system data, (ii) exergy analysis, and (iii) optimization through exergoenvironmental, exergoeconomic, and exergotechnical indicators, statistically assessed using the desirability function approach (DFA). The model was validated using a case study of a leachate treatment system that combined coagulation-flocculation, three photo-Fenton configurations, and activated sludge. The highest desirability (0.59) in exergy terms for the pretreatment was achieved with 1 g L<sup>-1</sup> iron chloride at pH 5, while DFA was 0.74 in the photo-Fenton process involved pretreated leachate with residual iron (0.08 g L<sup>-1</sup> of iron) and a single 2.5 g L<sup>-1</sup> dose of hydrogen peroxide followed by biological treatment. Irreversibilities were greatest in the biological stage due to electricity demand followed by influent composition, reagent consumption, and sludge generation. The model offers robust criteria for optimizing treatment design and supports the achievement of Sustainable Development Goals 6, 11, and 12.

Water Environment ResearchVol. 98(2)
Universidad del Norte (CO), Francisco de Paula Santander University (CO), University of Warwick (GB), University at Buffalo, State University of New York (US)
Openalex Percentile: Top 59%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Exergy Analysis for Evaluating the Performance of an Integrated Leachate Treatment System — Ricardo L. Mejía‐Marchena, Salvador Villamizar, et al. · Water Environment Research (2026) | TGRS Research Map | TGRS