Ultrasound-enabled refreshable electrochemical sensors for cardiac biomarker monitoring

Cardiac troponin I (cTnI) is the gold-standard biomarker for acute myocardial infarction, yet current laboratory-based high-sensitivity assays require centralized infrastructure, trained personnel, and serial testing, limiting their suitability for real-time or continuous monitoring in resource-limited settings. Point-of-care electrochemical sensors have shown promise for rapid cTnI detection, but their reliance on antibodies as biorecognition elements and redox mediator solutions, and single-use operation restricts practical translation. Here, we report an ultrasound-enabled refreshable electrochemical biosensor for sensitive, stable, and repeatable cTnI monitoring. The device employs a cTnI-specific peptide as the biorecognition element, providing enhanced stability during storage, transport, and operation. Label-free electrochemical impedance spectroscopy quantifies impedance changes upon cTnI binding in body fluids, including serum and saliva, enabling rapid analysis and high sensitivity with electroosmotic enhancement. The sensor achieves a wide dynamic range from 0.031 pg/mL to 1.5 ng/mL for cTnI detection and quantification in 15 min. Compared to previously reported electrochemical platforms and conventional laboratory-based high-sensitivity assays, the proposed sensor offers improved analytical performance, as defined by limit of detection, dynamic range, and assay time. Importantly, low-power ultrasound effectively refreshes the sensor by removing bound targets without damaging the peptide, enabling sustained measurements and prolonging sensor lifetime. The demonstrated sensitivity enhancement and refreshability establish a foundation for extending this approach to diverse biomarkers, paving the way for frequent molecular monitoring and early clinical intervention.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics
Published
2026-02-12
DOI
https://doi.org/10.1016/j.bios.2026.118519
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound-enabled refreshable electrochemical sensors for cardiac biomarker monitoring

Myeong Namkoong, A. Akcan-Arikan, Heng Guo, Mayank Garg et al.
Biosensors and Bioelectronics
Acoustic Wave Resonator Technologies
article

Ultrasound-enabled refreshable electrochemical sensors for cardiac biomarker monitoring

Myeong Namkoong, A. Akcan-Arikan, Heng Guo, Mayank Garg, Connor Malone, S. Rahman, Elizabeth Zhanov, Limei Tian
article en

Abstract

Cardiac troponin I (cTnI) is the gold-standard biomarker for acute myocardial infarction, yet current laboratory-based high-sensitivity assays require centralized infrastructure, trained personnel, and serial testing, limiting their suitability for real-time or continuous monitoring in resource-limited settings. Point-of-care electrochemical sensors have shown promise for rapid cTnI detection, but their reliance on antibodies as biorecognition elements and redox mediator solutions, and single-use operation restricts practical translation. Here, we report an ultrasound-enabled refreshable electrochemical biosensor for sensitive, stable, and repeatable cTnI monitoring. The device employs a cTnI-specific peptide as the biorecognition element, providing enhanced stability during storage, transport, and operation. Label-free electrochemical impedance spectroscopy quantifies impedance changes upon cTnI binding in body fluids, including serum and saliva, enabling rapid analysis and high sensitivity with electroosmotic enhancement. The sensor achieves a wide dynamic range from 0.031 pg/mL to 1.5 ng/mL for cTnI detection and quantification in 15 min. Compared to previously reported electrochemical platforms and conventional laboratory-based high-sensitivity assays, the proposed sensor offers improved analytical performance, as defined by limit of detection, dynamic range, and assay time. Importantly, low-power ultrasound effectively refreshes the sensor by removing bound targets without damaging the peptide, enabling sustained measurements and prolonging sensor lifetime. The demonstrated sensitivity enhancement and refreshability establish a foundation for extending this approach to diverse biomarkers, paving the way for frequent molecular monitoring and early clinical intervention.

Biosensors and BioelectronicsVol. 302
Texas A&M University System (US), Texas Children's Hospital (US), Texas A&M University (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 59%
Acoustic Wave Resonator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.