Visualisation of low-level radioactive materials using an omnidirectional rotating Compton camera in an accelerator-based boron neutron capture therapy facility employing a lithium target

<i>Objective</i>. We report the visualisation of low-level gamma radiation sources in an accelerator-based boron neutron capture therapy (AB-BNCT) facility employing a Li target. In this facility, irradiation of the Li target with accelerated protons produces neutrons and generates a large amount of radioactive7Be with a long half-life of 53 d, while various other radioactive materials are suspected to be produced through neutron activation.<i>Approach</i>. To visualise gamma rays emitted from these radioactive materials across a wide energy range with high sensitivity, we prepared a high-sensitivity omnidirectional rotating Compton camera comprising six 3.5 cm × 3.5 cm × 3.5 cm CsI(Tl) scintillator cubes mounted on a motorised rotation stage. Measurements were carried out in the irradiation room 24 h after neutron irradiation.<i>Main result</i>. No leakage of7Be from the Li target into the irradiation room was detected. However, some radioactive materials with long half-lives were observed in the irradiation port and on the bed. Additionally, gamma rays from7Be remaining in a spent Li target, previously removed from the irradiation port and stored, were visualised.<i>Significance</i>. The Compton camera technique proposed and used in this study is shown to be effective for monitoring radioactive materials within AB-BNCT facility.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2026-02-11
DOI
https://doi.org/10.1088/1361-6498/ae44a3
Primary Topic
Boron Compounds in Chemistry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visualisation of low-level radioactive materials using an omnidirectional rotating Compton camera in an accelerator-based boron neutron capture therapy facility employing a lithium target

Hiromichi Ishiyama, Takahiro Mizoguchi, Saki Ishikawa, T. Watanabe et al.
Journal of Radiological Protection
Boron Compounds in Chemistry
article

Visualisation of low-level radioactive materials using an omnidirectional rotating Compton camera in an accelerator-based boron neutron capture therapy facility employing a lithium target

Hiromichi Ishiyama, Takahiro Mizoguchi, Saki Ishikawa, T. Watanabe, Kenzi Shimada, Kosuke Ohkubo, Daisuke Kano, Masaru Nakamura, Hikari Tsukamoto, Satoshi Nakamura, Yusuke Watanabe, Hiroshi Muraishi, Ryoji Enomoto, Mika Kagaya
article en

Abstract

<i>Objective</i>. We report the visualisation of low-level gamma radiation sources in an accelerator-based boron neutron capture therapy (AB-BNCT) facility employing a Li target. In this facility, irradiation of the Li target with accelerated protons produces neutrons and generates a large amount of radioactive7Be with a long half-life of 53 d, while various other radioactive materials are suspected to be produced through neutron activation.<i>Approach</i>. To visualise gamma rays emitted from these radioactive materials across a wide energy range with high sensitivity, we prepared a high-sensitivity omnidirectional rotating Compton camera comprising six 3.5 cm × 3.5 cm × 3.5 cm CsI(Tl) scintillator cubes mounted on a motorised rotation stage. Measurements were carried out in the irradiation room 24 h after neutron irradiation.<i>Main result</i>. No leakage of7Be from the Li target into the irradiation room was detected. However, some radioactive materials with long half-lives were observed in the irradiation port and on the bed. Additionally, gamma rays from7Be remaining in a spent Li target, previously removed from the irradiation port and stored, were visualised.<i>Significance</i>. The Compton camera technique proposed and used in this study is shown to be effective for monitoring radioactive materials within AB-BNCT facility.

Journal of Radiological ProtectionVol. 46(1)
National Cancer Centre Japan (JP), Sendai National College of Technology (JP), Toshima Manufacturing (Japan) (JP), National Cancer Center (US), Kitasato University Hospital (JP), Tokai University Hospital (JP), The Cancer Institute Hospital (JP), National Cancer Center Hospital East (JP), Ibaraki University (JP), Kitasato University (JP)
Affordable and clean energy
Openalex Percentile: Top 59%
Boron Compounds in Chemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.