MRgLITT under general anesthesia using extended non-ferromagnetic components in a non-MR-compatible environment-a case report

Magnetic resonance-guided laser interstitial thermal therapy (MRgLITT) is a novel minimally invasive treatment that requires precise implementation within a magnetic resonance (MR) environment. Given the procedure’s lengthy duration and the need for absolute immobility, general anesthesia (GA) with endotracheal intubation (ETT) and an MR-compatible ventilator is recommended. However, in facilities lacking a hybrid MR operating room or MR-compatible anesthesia equipment, alternative anesthesia strategies must be employed to ensure patient safety while complying with American Society of Anesthesiologists (ASA) recommendations for sedation and GA in the MRI environment, including monitoring of heart rate, pulse oximetry, and blood pressure. A 43-year-old male ASA II patient, with epilepsy and cavernous hemangioma, was scheduled for elective MRgLITT. The critical second phase of this procedure required GA with ETT within the MRI environment. Due to the absence of MR-conditional anesthesia equipment in the MR suite, extended-length, MR-safe components were adapted from existing equipment. These modifications included a prolonged breathing circuit, an extended-length cable for the pulse oximeter probe, an extended air-conduction tube for non-invasive blood pressure (NIBP), and a prolonged sampling line for the capnograph. The effectiveness and safety of these adapted devices were verified against standard monitoring equipment and a conventional anesthesia machine in the pre-procedural test conducted during the first phase of MRgLITT. Furthermore, arterial blood gas analysis provided additional confirmation of patient safety using the modified hardware. By using these extended lines, conventional ventilators and monitors can be positioned outside the MR scanner room, enabling continuous support and monitoring of the patient’s vital signs throughout the procedure. The patient was very stable intraoperatively, particularly in the MR suite, which required extended equipment. Ultimately, the MRgLITT was successfully completed using this innovative anesthesia management approach. The patient recovered very quickly. In the absence of MR-compatible equipment, adapted non-ferrous devices with extended-length components can provide necessary physiologic support and monitoring, aligning with ASA guidelines for sedation and GA in an MRI environment. However, rigorous pre-procedural testing of such modified equipment is essential to ensure patient safety. The innovative anesthesia approach we implemented for MR-guided procedures demonstrates clinical utility and offers a practical model for anesthesiologists managing similar resource-constrained scenarios.

Authors

Institutions

Publication Details

Journal
BMC Anesthesiology
Published
2026-02-12
DOI
https://doi.org/10.1186/s12871-026-03692-4
Primary Topic
Anesthesia and Sedative Agents
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MRgLITT under general anesthesia using extended non-ferromagnetic components in a non-MR-compatible environment-a case report

Jun Xiong, Jinqi Lin, Zhijing Yang, Yi Su et al.
BMC Anesthesiology
Anesthesia and Sedative Agents
article

MRgLITT under general anesthesia using extended non-ferromagnetic components in a non-MR-compatible environment-a case report

Jun Xiong, Jinqi Lin, Zhijing Yang, Yi Su, Ruibo Zhang, Long Chen, Lu Li, Yan Huang, Yong Chen
article en

Abstract

Magnetic resonance-guided laser interstitial thermal therapy (MRgLITT) is a novel minimally invasive treatment that requires precise implementation within a magnetic resonance (MR) environment. Given the procedure’s lengthy duration and the need for absolute immobility, general anesthesia (GA) with endotracheal intubation (ETT) and an MR-compatible ventilator is recommended. However, in facilities lacking a hybrid MR operating room or MR-compatible anesthesia equipment, alternative anesthesia strategies must be employed to ensure patient safety while complying with American Society of Anesthesiologists (ASA) recommendations for sedation and GA in the MRI environment, including monitoring of heart rate, pulse oximetry, and blood pressure. A 43-year-old male ASA II patient, with epilepsy and cavernous hemangioma, was scheduled for elective MRgLITT. The critical second phase of this procedure required GA with ETT within the MRI environment. Due to the absence of MR-conditional anesthesia equipment in the MR suite, extended-length, MR-safe components were adapted from existing equipment. These modifications included a prolonged breathing circuit, an extended-length cable for the pulse oximeter probe, an extended air-conduction tube for non-invasive blood pressure (NIBP), and a prolonged sampling line for the capnograph. The effectiveness and safety of these adapted devices were verified against standard monitoring equipment and a conventional anesthesia machine in the pre-procedural test conducted during the first phase of MRgLITT. Furthermore, arterial blood gas analysis provided additional confirmation of patient safety using the modified hardware. By using these extended lines, conventional ventilators and monitors can be positioned outside the MR scanner room, enabling continuous support and monitoring of the patient’s vital signs throughout the procedure. The patient was very stable intraoperatively, particularly in the MR suite, which required extended equipment. Ultimately, the MRgLITT was successfully completed using this innovative anesthesia management approach. The patient recovered very quickly. In the absence of MR-compatible equipment, adapted non-ferrous devices with extended-length components can provide necessary physiologic support and monitoring, aligning with ASA guidelines for sedation and GA in an MRI environment. However, rigorous pre-procedural testing of such modified equipment is essential to ensure patient safety. The innovative anesthesia approach we implemented for MR-guided procedures demonstrates clinical utility and offers a practical model for anesthesiologists managing similar resource-constrained scenarios.

BMC AnesthesiologyVol. 26(1)
Shenzhen University (CN), University Town of Shenzhen (CN), Shenzhen University Health Science Center (CN)
Openalex Percentile: Top 57%
Anesthesia and Sedative Agents
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.