Deep Eutectic Solvent Extraction for Liquid Chromatographic Analysis of Capecitabine and Related Metabolites in Human Plasma

We applied the deep eutectic solvent (DES) extraction for analyzing capecitabine (Cape), 5’-deoxy-5-fluorocytidine (DFCR), 5’-deoxy-5-fluorouridine (DFUR), and 5-fluorouracil (5-FU) in human plasma with LC–UV method. In this method, the DES, which was prepared by mixing trioctylmethylammonium chloride and pentafluorophenol in a 1:2 molar ratio, was used as extraction solvent for target analytes in the sample solution. The target analytes extracted by DES was then injected into a reversed-phase LC–UV system and were detected with ultraviolet at 270 nm for 5-FU, DFCR, and DFUR, and at 240 nm for Cape. Under the optimized conditions, this extraction resulted in enrichment factors for Cape, DFCR, DFUR, and 5-FU, ranging from 1.4 to 5.6. The determination coefficients of the calibration curves were r2 > 0.9952 in the range of 0.05–10 µg/mL. The limits of detection and quantification ranged from 1.9 to 4.4 and from 6.4 to 14.7 ng/mL, respectively. The relative standard deviations of the peak areas obtained during intra-day determinations were within 9.8 %. The proposed method was further validated by the analysis of spiked human plasma samples.

Authors

Institutions

Publication Details

Journal
Chromatography
Published
2026-02-11
DOI
https://doi.org/10.15583/jpchrom.2025.025
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Eutectic Solvent Extraction for Liquid Chromatographic Analysis of Capecitabine and Related Metabolites in Human Plasma

Tadashi Hayama, Nao Nishijo, Miki Yokoya, Makoto TAKADA
Chromatography
Analytical chemistry methods development
article

Deep Eutectic Solvent Extraction for Liquid Chromatographic Analysis of Capecitabine and Related Metabolites in Human Plasma

Tadashi Hayama, Nao Nishijo, Miki Yokoya, Makoto TAKADA
article en

Abstract

We applied the deep eutectic solvent (DES) extraction for analyzing capecitabine (Cape), 5’-deoxy-5-fluorocytidine (DFCR), 5’-deoxy-5-fluorouridine (DFUR), and 5-fluorouracil (5-FU) in human plasma with LC–UV method. In this method, the DES, which was prepared by mixing trioctylmethylammonium chloride and pentafluorophenol in a 1:2 molar ratio, was used as extraction solvent for target analytes in the sample solution. The target analytes extracted by DES was then injected into a reversed-phase LC–UV system and were detected with ultraviolet at 270 nm for 5-FU, DFCR, and DFUR, and at 240 nm for Cape. Under the optimized conditions, this extraction resulted in enrichment factors for Cape, DFCR, DFUR, and 5-FU, ranging from 1.4 to 5.6. The determination coefficients of the calibration curves were r2 > 0.9952 in the range of 0.05–10 µg/mL. The limits of detection and quantification ranged from 1.9 to 4.4 and from 6.4 to 14.7 ng/mL, respectively. The relative standard deviations of the peak areas obtained during intra-day determinations were within 9.8 %. The proposed method was further validated by the analysis of spiked human plasma samples.

Chromatography
Fukuoka University (JP)
Fukuoka University
Life below water
Openalex Percentile: Top 57%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.