Nonenzymatic Glucose Biosensor Based on Selective Reduction of Silver Ions

A nonenzymatic conductivity-based glucose biosensor, reported here, designed for potential noninvasive measurement in accessible biofluids such as saliva, sweat, and tears. The sensor exploits a classic Tollens' silvering process that deposits metallic silver on a sensitized surface via a quantitative, selective reduction of silver ions by glucose. Of the two surface sensitization methods used, the self-assembled bifunctional thiol/silane surfactant yields a more stable and sensitive sensor than tin-(II) chloride. The conductometric sensor consists of two spiral interdigitated silver electrodes fabricated by lithography and wet etching. The sensor impedance changes after selective metallic silver deposition between the electrodes. The sensor exhibits a sigmoidal response in a wide range of glucose concentrations from 200 mg/dL to less than 0.2 mg/dL and an ultralow limit of detection (ULOD) of 0.3 × 10<sup>-5</sup> mg/dL. The ULOD is attributed to the percolation network morphology of the deposited silver, connecting two electrodes (fractal dimension <i>D</i> = 1.5) that function like parallel nanoresistors. The log-log plot of conductivity vs glucose concentration yields a conductivity exponent that increases from 1 to 2, predicted for a 2D to 3D percolation transition in going from ultralow to high glucose concentration.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-02-11
DOI
https://doi.org/10.1021/acsomega.5c08894
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nonenzymatic Glucose Biosensor Based on Selective Reduction of Silver Ions

Shankar B. Rananavare, Maryam Sarlak
ACS Omega
Electrochemical sensors and biosensors
article

Nonenzymatic Glucose Biosensor Based on Selective Reduction of Silver Ions

Shankar B. Rananavare, Maryam Sarlak
article en

Abstract

A nonenzymatic conductivity-based glucose biosensor, reported here, designed for potential noninvasive measurement in accessible biofluids such as saliva, sweat, and tears. The sensor exploits a classic Tollens' silvering process that deposits metallic silver on a sensitized surface via a quantitative, selective reduction of silver ions by glucose. Of the two surface sensitization methods used, the self-assembled bifunctional thiol/silane surfactant yields a more stable and sensitive sensor than tin-(II) chloride. The conductometric sensor consists of two spiral interdigitated silver electrodes fabricated by lithography and wet etching. The sensor impedance changes after selective metallic silver deposition between the electrodes. The sensor exhibits a sigmoidal response in a wide range of glucose concentrations from 200 mg/dL to less than 0.2 mg/dL and an ultralow limit of detection (ULOD) of 0.3 × 10<sup>-5</sup> mg/dL. The ULOD is attributed to the percolation network morphology of the deposited silver, connecting two electrodes (fractal dimension <i>D</i> = 1.5) that function like parallel nanoresistors. The log-log plot of conductivity vs glucose concentration yields a conductivity exponent that increases from 1 to 2, predicted for a 2D to 3D percolation transition in going from ultralow to high glucose concentration.

ACS OmegaVol. 11(9)
Portland State University (US)
Clean water and sanitation
Openalex Percentile: Top 59%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.