RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF METFORMIN, EMPAGLIFLOZIN AND LINAGLIPTIN IN ITS BULK AND COMBINED TABLET DOSEAGE FORM

A simple, precise, accurate, and stability-indicating reverse phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous estimation of Metformin (MET), Empagliflozin (EMP), and Linagliptin (LIN) in bulk drugs and combined tablet dosage forms. Chromatographic separation was achieved using a C18 column with a mobile phase consisting of phosphate buffer and methanol in an optimized ratio, delivered at a suitable flow rate, and detection was carried out using a UV/PDA detector. The method provided well-resolved peaks with satisfactory retention times, good peak symmetry, and acceptable system suitability parameters. The proposed method was validated according to ICH guidelines for parameters including accuracy, precision, linearity, range, specificity, robustness, limit of detection (LOD), and limit of quantification (LOQ). Linearity was observed over the selected concentration ranges for all three drugs with correlation coefficients greater than 0.99. Accuracy studies showed percentage recoveries within acceptable limits, indicating the reliability of the method. Precision studies demonstrated low %RSD values, confirming repeatability and intermediate precision. The method was found to be robust against small deliberate variations in chromatographic conditions. Forced degradation studies under acidic, alkaline, oxidative, thermal, and photolytic conditions confirmed that the method is stability-indicating, as degradation products did not interfere with the analyte peaks. The developed RP-HPLC method is suitable for routine quality control analysis and stability testing of MET, EMP, and LIN in pharmaceutical formulations.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-02-11
DOI
https://doi.org/10.5281/zenodo.18604496
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF METFORMIN, EMPAGLIFLOZIN AND LINAGLIPTIN IN ITS BULK AND COMBINED TABLET DOSEAGE FORM

Kumbha Prathyusha1*, Poli Sai Padma Priya2, Koppula Jaya Nissi3, Kolasani Venkata Ramaiah4, Mamillapalli Mohan Krishna5
Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF METFORMIN, EMPAGLIFLOZIN AND LINAGLIPTIN IN ITS BULK AND COMBINED TABLET DOSEAGE FORM

Kumbha Prathyusha1*, Poli Sai Padma Priya2, Koppula Jaya Nissi3, Kolasani Venkata Ramaiah4, Mamillapalli Mohan Krishna5
article en

Abstract

A simple, precise, accurate, and stability-indicating reverse phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous estimation of Metformin (MET), Empagliflozin (EMP), and Linagliptin (LIN) in bulk drugs and combined tablet dosage forms. Chromatographic separation was achieved using a C18 column with a mobile phase consisting of phosphate buffer and methanol in an optimized ratio, delivered at a suitable flow rate, and detection was carried out using a UV/PDA detector. The method provided well-resolved peaks with satisfactory retention times, good peak symmetry, and acceptable system suitability parameters. The proposed method was validated according to ICH guidelines for parameters including accuracy, precision, linearity, range, specificity, robustness, limit of detection (LOD), and limit of quantification (LOQ). Linearity was observed over the selected concentration ranges for all three drugs with correlation coefficients greater than 0.99. Accuracy studies showed percentage recoveries within acceptable limits, indicating the reliability of the method. Precision studies demonstrated low %RSD values, confirming repeatability and intermediate precision. The method was found to be robust against small deliberate variations in chromatographic conditions. Forced degradation studies under acidic, alkaline, oxidative, thermal, and photolytic conditions confirmed that the method is stability-indicating, as degradation products did not interfere with the analyte peaks. The developed RP-HPLC method is suitable for routine quality control analysis and stability testing of MET, EMP, and LIN in pharmaceutical formulations.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 57%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.