Study on the Thermal Comfort in Office Buildings adopting Low Velocity Air Circulation and Displacement Ventilation Systems

Abstract With the improvement of living standards, the demand for indoor comfort has increased. Fan coil systems have been found to cause uneven indoor temperature distribution, strong drafts, airflow short-circuiting, stagnant zones, and high noise levels during long-term use, thereby failing to ensure thermal comfort for occupants.This study investigates airflow characteristics and thermal comfort under low-velocity indoor air circulation. By adjusting fan coil and dehumidified displacement ventilation parameters, a more comfortable and healthier environment is achieved. The research focuses on a typical office fan coil unit with fresh air system. Environmental parameters were measured and recorded on an experimental platform in summer and winter to analyze the impact of different fan coil air parameters on indoor airflow and thermal comfort.The study shows that under low velocity air circulation(LVAC), short air jets cause temperature differences in the working area. However, the building envelope's insulation, airflow kinetics, and temperature field diffusion maintain stable indoor airflow and acceptable temperature uniformity. Compared to traditional systems, low-velocity systems reduce maximum air velocity by 62% in winter and 20% in summer, with a draft dissatisfaction coefficient (DR) of only 28%–61%. For long-term seated occupants, optimal temperature settings and well-insulated envelopes are required.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Science and Engineering Applications
Published
2026-02-11
DOI
https://doi.org/10.1115/1.4071103
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Thermal Comfort in Office Buildings adopting Low Velocity Air Circulation and Displacement Ventilation Systems

Junbo Shen, Jianzhong Chen, Wenxin Xia, Yixiao Bu et al.
Journal of Thermal Science and Engineering Applications
Infection Control and Ventilation
article

Study on the Thermal Comfort in Office Buildings adopting Low Velocity Air Circulation and Displacement Ventilation Systems

Junbo Shen, Jianzhong Chen, Wenxin Xia, Yixiao Bu, Zhao Li
article en

Abstract

Abstract With the improvement of living standards, the demand for indoor comfort has increased. Fan coil systems have been found to cause uneven indoor temperature distribution, strong drafts, airflow short-circuiting, stagnant zones, and high noise levels during long-term use, thereby failing to ensure thermal comfort for occupants.This study investigates airflow characteristics and thermal comfort under low-velocity indoor air circulation. By adjusting fan coil and dehumidified displacement ventilation parameters, a more comfortable and healthier environment is achieved. The research focuses on a typical office fan coil unit with fresh air system. Environmental parameters were measured and recorded on an experimental platform in summer and winter to analyze the impact of different fan coil air parameters on indoor airflow and thermal comfort.The study shows that under low velocity air circulation(LVAC), short air jets cause temperature differences in the working area. However, the building envelope's insulation, airflow kinetics, and temperature field diffusion maintain stable indoor airflow and acceptable temperature uniformity. Compared to traditional systems, low-velocity systems reduce maximum air velocity by 62% in winter and 20% in summer, with a draft dissatisfaction coefficient (DR) of only 28%–61%. For long-term seated occupants, optimal temperature settings and well-insulated envelopes are required.

Journal of Thermal Science and Engineering Applications
University of Shanghai for Science and Technology (CN), Shanghai Research Institute of Building Sciences (China) (CN)
Sustainable cities and communities
Openalex Percentile: Top 61%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on the Thermal Comfort in Office Buildings adopting Low Velocity Air Circulation and Displacement Ventilation Systems — Junbo Shen, Jianzhong Chen, et al. · Journal of Thermal Science and Engineering Applications (2026) | TGRS Research Map | TGRS